Tripp-lite SmartOnline 230V 1kVA 900W On-Line UPS, Tower, Network SUINT1000XLCD

Tripp-lite SmartOnline 230V 1kVA 900W On-Line UPS, Tower, Network  SUINT1000XLCD
Tripp-lite SmartOnline 230V 1kVA 900W On-Line UPS, Tower, Network  SUINT1000XLCD
Tripp-lite SmartOnline 230V 1kVA 900W On-Line UPS, Tower, Network  SUINT1000XLCD
Tripp-lite SmartOnline 230V 1kVA 900W On-Line UPS, Tower, Network  SUINT1000XLCD

Tripp-lite SmartOnline 230V 1kVA 900W On-Line UPS, Tower, Network SUINT1000XLCD

Regular price 555,000 IQD
/
Tax included. Shipping calculated at checkout.
\

Specifications

OVERVIEW
UPC Code 037332190659
UPS Type On-Line
INPUT
Rated input current (Maximum Load) 4.9A 220V; 4.7A 230V; 4.5A 240V
Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC
Nominal Input Voltage Description 230V factory default
UPS Input Connection Type C14 inlet
Input Circuit Breakers 10A
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.1
Recommended Electrical Service 230V
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 1000
Output Capacity (kVA) 1
Output Watt Capacity (Watts) 900
Output kW Capacity (kW) 0.9
Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits)
Power Factor   0.9
Crest Factor 3:1
Nominal Voltage Details 230V default
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz; BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 3%
Included Output Power Cables Includes two C13 to C14 power cables
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Output Receptacles (4) C13
Individually Controllable Load Banks   No
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 4.8 min. (900w)
Half Load Runtime (min.)   12.8 min. (450w)
Expandable Battery Runtime Extended runtime supported via optional external battery packs
Expandable Runtime Yes
Expandable Runtime Description External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details
External Battery Pack Compatibility   BP24V15RT2U  (limit 1);  BP24V28-2U  (limit 1);  BP24V70-3U  (multi-pack compatible)
DC System Voltage (VDC) 24
Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge)
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction 2% output voltage regulation during overvoltages to 280
Undervoltage Correction   2% output voltage regulation during undervoltages to 80V (50% load), 175V (100% load)

Pickup is available at our Baghdad Branch.

Location: Baghdad-62st-near Saj Alreef

Call/Whatsapp: 07834927717

Order is usually ready within 24 hours.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

More from UPS
Zeus 3000VA Online UPS
540,000 IQD
Sold Out
Zeus 2600VA UPS
120,000 IQD
APC Smart-UPS C 1500VA LCD 230V SMC1500IC
640,000 IQD
APC Easy UPS On-Line SRV 2000VA 230V
945,000 IQD
APC Back-UPS 750VA, 230V, AVR, IEC Sockets (410 W)
130,000 IQD
APC Back-UPS 1600VA, 230V, AVR, IEC Sockets (900 W) (BX1600MI)
275,000 IQD