Tripp-Lite martOnline 208/230V 1.5kVA 1.35kW UPS, 2U, SNMP Card Option, LCD SUINT1500LCD2U

Tripp-Lite martOnline 208/230V 1.5kVA 1.35kW UPS, 2U, SNMP Card Option, LCD SUINT1500LCD2U
Tripp-Lite martOnline 208/230V 1.5kVA 1.35kW UPS, 2U, SNMP Card Option, LCD SUINT1500LCD2U

Tripp-Lite martOnline 208/230V 1.5kVA 1.35kW UPS, 2U, SNMP Card Option, LCD SUINT1500LCD2U

Regular price $700.00
/
Tax included. Shipping calculated at checkout.
OUTPUT
Output Volt Amp Capacity (VA) 1500
Output kVA Capacity (kVA) 1.5
Output Watt Capacity (Watts) 1350
Output kW Capacity (kW) 1.35
Output Capacity Details DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 945 watts for 208/220/230/240V output voltages; Max output is 1080W (756W in Frequency Conversion mode) at 200V output voltage OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).
Power Factor 0.9
Crest Factor 3:1
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
Nominal Voltage Details Nominal output voltage is user configured on first power-on
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 2%
Output Receptacles (6) C13
Included Output Power Cables Includes 2 C13 to C14 power cables
Load Management Receptacles Two switchable 2-outlet load banks
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
INPUT
Rated input current (Maximum Load) 7.49A
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection Type C14 inlet
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 4.5 min. (1350w)
Half Load Runtime (min.) 12.6 min. (675w)
Expandable Battery Runtime Supports extended runtime with optional external battery packs
External Battery Pack Compatibility  BP36V15-2U (limit 1); BP36V27-2US (multi-pack compatible); BP36V42-3U (multi-pack compatible)
DC System Voltage (VDC) 36
Battery Recharge Rate (Included Batteries) Less than 5.8 hours from 10% to 90% (typical, full load discharge)
Internal UPS Replacement Battery Cartridge RBC36S
Battery Access Front panel battery access door
Battery Replacement Description Hot-swappable, replaceable batteries
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction 2% output voltage regulation during overvoltages to 288V
Undervoltage Correction 2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options
Switches 5 front panel switches: On/Off, Up, Down and Escape
Alarm Cancel Operation Power-fail alarm can be silenced by following on-screen prompts
Audible Alarm Audible alarm indicates power failure, low battery, overload and fault
LED Indicators 4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)
SURGE / NOISE SUPPRESSION
UPS Dataline Suppression Details Single line dialup / network dataline protection included
EMI / RFI AC Noise Suppression Yes
AC Suppression Joule Rating 936
AC Suppression Response Time Instantaneous
PHYSICAL
Included Mounting Accessory Description 4 post installation accessories included
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary Form Factor Rackmount
UPS Power Module Dimensions (hwd, cm) 8.79 x 43.79 x 49.61
Rack Height (U Spaces) 2
Minimum Required Rack Depth without External Battery Pack (cm) 40
Minimum Required Rack Depth with External Battery Pack (cm) 42
Minimum Required Rack Depth without External Battery Pack (in.) 15.75
Minimum Required Rack Depth with External Battery Pack (in.) 16.5
UPS Power Module Weight (kg) 20.36
Shipping Dimensions (hwd / cm) 24.00 x 56.49 x 70.00
Shipping Weight (kg) 24.43
Cooling Method Fan
UPS Housing Material Metal
Primary UPS Height (mm) 88
Primary UPS Width (mm) 438
Primary UPS Depth (mm) 496
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity 5 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 330
AC Economy Mode BTU / Hr. (Full Load) 142
Battery Mode BTU / Hr. (Full Load) 689
AC Mode Efficiency Rating (100% Load) >93%
AC Economy Mode Efficiency Rating (100% Load) >97%
Audible Noise <45dB at front side 1M
COMMUNICATIONS
Communications Interface USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Network Management Cards SNMPWEBCARD; WEBCARDLX 
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode; 2-12 ms. transfer time during economy mode operation
Low Voltage Transfer to Battery Power (Setpoint) 160V (100% load), 140V (66% load), 120V (33% load)
High Voltage Transfer to Battery Power (Setpoint) 288V
SPECIAL FEATURES
Grounding Lug Back panel grounding lug included
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Automatic inverter bypass; Hot swappable batteries
Green Energy-Saving Features High efficiency economy mode operation; Individually controllable load banks
CERTIFICATIONS
UPS Certifications CE; ENERGY STAR Qualified; Tested to CSA (Canada); Tested to EAC (Belarus, Kazakhstan, Russia); Tested to SASO (Saudi Arabia); Tested to UL1778 (USA)
UPS Certification Details IEC62040-1:2008+A1; UL1778 5th; Meets EMI approvals IEC62040-2:2006; FCC Part 15

Pickup is available at our Baghdad Branch.

Location: Baghdad-62st-near Saj Alreef

Call/Whatsapp: 07834927717

Order is usually ready within 24 hours.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

More from All Products
HP Ink 123
$10.50
HP 652 Black/Tri-color Original Ink Cartridge
$12.50
HP 953 Original Ink Cartidge
from $20.00
HP Ink 72
$80.00
HP 711 80-ml DesignJet Ink Cartridge
$35.00
HP Toner 415A
from $80.00
Recently viewed