Power
Tripp-Lite Tripp-Lite UK Power Cable - C19 to BS1363, 13A, 250V, 16 AWG, 8 ft. BS1363 Plug (2.4 m), Black
PC Code 037332141996 Country/Region UK Power Cord Application Server INPUT Maximum Input Amps 13 Cable Length (m) 2.4 Voltage Compatibility (VAC) 250 PHYSICAL Power Cord Jacket Type SJT Wire Gauge (OD - mm²) 1.29 Shipping Dimensions (hwd / cm) 0.64 x 14.48 x 17.53 Shipping Weight (kg) 0.41 Color Black Number of Conductors 3 CONNECTIONS Side A - Connector 1 BS1363 UK PLUG Side B - Connector 1 IEC-320-C19 WARRANTY Product Warranty Period (Worldwide) Lifetime limited warranty
9,000 IQD - 22,000 IQD
Tripp-Lite Tripp-Lite C14 Male to C13 Female Splitter - C14 to 2x C13, 10A, 100-250V, 18 AWG,
UPC Code 037332154750 Country/Region North America Power Cord Application PC; Monitor; Server; PDU; UPS INPUT Maximum Input Amps 10 Cable Length (m) 1.8 Voltage Compatibility (VAC) 100-250 PHYSICAL Power Cord Jacket Type SJT Wire Gauge (OD - mm²) 0.82 Shipping Dimensions (hwd / cm) 25.40 x 17.78 x 1.27 Shipping Weight (kg) 0.33 Color Black Number of Conductors 3 CONNECTIONS Side A - Connector 1 IEC-320-C14 Side B - Connector 1 (2) IEC-320-C13 WARRANTY Product Warranty Period (Worldwide) Lifetime limited warranty
8,000 IQD - 12,000 IQD
Tripp-Lite Tripp-Lite 2-Port 4K 3D HDMI Splitter, HDMI 2.0, HDCP 2.2, Ultra HD 4K x 2K Audio/Video, 3840 x 2160 @ 60 Hz,
chnology HDMI (All types) INPUT External Power Supply Input Specs (V / Hz / A) 100-240V, 50/60HZ, 0.35A External Power Supply Output Specs (V / A) 5V, 2A External Power Supply Cord Length (ft.) 4.0 External Power Supply Cord Length (m.) 1.2 External Power Supply Plug(s) NEMA 5-15P North America; CEE 7/16 Schuko; BS 1363 UK; AS/NZS 3112 Australia External Power Supply Certifications CE; FCC; UL; cUL; TUV; CCC; PSE; C-Tick; GS; RoHS Bus Powered No USER INTERFACE, ALERTS & CONTROLS LED Indicators (x1) Green (Power), (x2) Orange (Signal) PHYSICAL Shipping Dimensions (hwd / cm) 5.51 x 18.39 x 16.41 Shipping Weight (kg) 0.45 Material of Construction Metal Color Black Rackmountable Yes ENVIRONMENTAL Operating Temperature Range 32 to 104 F (0 to 40 C) Storage Temperature Range 5 to 122 F (-15 to 50 C) Relative Humidity 0% to 85% RH, Non-Condensing CONNECTIONS Ports 2 Side A - Connector 1 HDMI (FEMALE) Side B - Connector 1 (2) HDMI (FEMALE) Connector Plating Nickel FEATURES & SPECIFICATIONS Max Supported Video Resolution 3840 x 2160 @ 60Hz HDMI Specification 2.0 HDCP Specification 2.2 Audio Specification DTS-HD, Dolby TrueHD, Dolby Digial Plus, and LPCM 7.1 Channel Surround Sound Driver Required No Max Supported Color Depth 36-bit Deep Color EDID Compatible Yes 3D Video Supported Yes CERTIFICATIONS Certifications Tested to FCC, CE, ROHS Part Number (B118-002-UHD-2) WARRANTY Product Warranty Period (Worldwide) 3-year limited warranty
76,000 IQD
Tripp-Lite Tripp-Lite Cat6 Gigabit Bulk Solid PVC Cable - Blue, 1000-ft. (N222-01K-BL)
Technology Cat6 INPUT Cable Length (m) 304.8 PHYSICAL Shipping Dimensions (hwd / cm) 35.00 x 35.99 x 35.00 Shipping Weight (kg) 12.70 Color Blue CONNECTIONS Side A - Connector 1 BARE WIRE Side B - Connector 1 BARE WIRE CERTIFICATIONS Approvals UL verified, meets EIA/TIA CAT6 TIA/EIA- 568-B-2.1, DRAFT 9 standards WARRANTY Product Warranty Period (Worldwide) Lifetime limited warranty
200,000 IQD
Tripp-Lite Tripp-Lite 230V Automatic Voltage Switch with Surge Protection, 190 Joules, Direct Plug-In (AVS5D)
OUTPUT Frequency Compatibility 50 / 60 Hz Output Receptacles (1) British BS 1363A Right-Angle Outlets No INPUT Nominal Input Voltage(s) Supported 220V AC Recommended Electrical Service 230V Input Connection Type BS 1363 UK plug Input Cord Details Direct Plug-In Input Cord Length (m) 0.00 Voltage Compatibility (VAC) 230 Maximum Surge Amps 4500kA Right-Angle Plug No SURGE / NOISE SUPPRESSION AC Suppression Joule Rating 190 AC Suppression Response Time <1ns DATALINE SURGE SUPPRESSION Telephone/DSL Protection No Cable (Coax) Protection No Network (Ethernet) Protection No PHYSICAL Shipping Dimensions (hwd / cm) 13.49 x 8.59 x 6.60 Shipping Weight (kg) 0.18 Unit Dimensions (hwd / cm) 13.21 x 6.40 x 4.78 Material of Construction Plastic Housing Color Black Anti-Microbial Protected No CERTIFICATIONS Certifications CE Approvals RoHS
18,000 IQD
Tripp-Lite Tripp-Lite 230V Automatic Voltage Switch with Surge Protection, 380 Joules, Hardwired (AVS30D )
OUTPUT Output Receptacles Hardwire Output Amp Capacity 30 Right-Angle Outlets No INPUT Nominal Input Voltage(s) Supported 220V AC Recommended Electrical Service 230V Input Connection Type Hard-wire Input Cord Length (m) 0.00 Voltage Compatibility (VAC) 230 Maximum Surge Amps 6500kA Right-Angle Plug No SURGE / NOISE SUPPRESSION AC Suppression Joule Rating 380 AC Suppression Response Time <1ns DATALINE SURGE SUPPRESSION Telephone/DSL Protection Yes Cable (Coax) Protection No Network (Ethernet) Protection No PHYSICAL Shipping Dimensions (hwd / cm) 6.10 x 13.21 x 23.37 Shipping Weight (kg) 0.54 Unit Dimensions (hwd / cm) 17.78 x 13.31 x 5.537 Material of Construction Plastic Housing Color Black Anti-Microbial Protected No CERTIFICATIONS Certifications CE Approvals RoHS
40,000 IQD
Tripp-Lite Tripp-Lite SmartOnline 208/230V 3kVA 2.7kW Double-Conversion UPS, 2U Rack/Tower SUINT3000LCD2U
OUTPUT Output Volt Amp Capacity (VA) 3000 Output kVA Capacity (kVA) 3 Output Watt Capacity (Watts) 2700 Output kW Capacity (kW) 2.7 Output Capacity Details DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1890 watts for 208/220/230/240V output voltages; Max output is reduced to 2160W at 200V output voltage in all operating modes OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits). Power Factor 0.9 Crest Factor 3:1 Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V Nominal Voltage Details Nominal output voltage is user configured on first power-on Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 2% Output Receptacles (8) C13; (2) C19 Included Output Power Cables Includes 2 C13 to C14 and 1 C19 to C20 power cables Load Management Receptacles Two switchable 4 outlet load banks (3 C13 and 1 C19 per bank) Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave INPUT Rated input current (Maximum Load) 14.97A Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC UPS Input Connection Type C20 inlet Input Phase Single-Phase BATTERY Full Load Runtime (min.) 5 min. (2700w) Half Load Runtime (min.) 13.5 min. (1350w) Expandable Battery Runtime Supports extended runtime with optional external battery packs External Battery Pack Compatibility BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) DC System Voltage (VDC) 72 Battery Recharge Rate (Included Batteries) 3.0 hours from 10% to 90% (typical, full load discharge) Internal UPS Replacement Battery Cartridge RBC72S Battery Access Front panel battery access door Battery Replacement Description Hot-swappable, replaceable batteries Expandable Runtime Yes
1,875,000 IQD
Tripp-Lite Tripp-Lite SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, SMX3000XLRT2UA
3kVA / 3000VA / 2700W line interactive 2U rack/tower UPS, Sine Wave Extended runtime options up to 2700W, 0.9 Power Factor, Interactive LCD interface 98% line-mode efficiency, 2 switched load banks, 4 post mounting kit USB, RS232, EPO and slot for network management card options230V C20 inlet, 8 C13 & 1 C19 outlets Add optional WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature 2-year limited warranty
1,000,000 IQD
Tripp-Lite Tripp-Lite SmartOnline 230V 3kVA 2700W On-Line Double-Conversion UPS, Tower, SUINT3000XLCD
OUTPUT Output Volt Amp Capacity (VA) 3000 Output kVA Capacity (kVA) 3 Output Watt Capacity (Watts) 2700 Output kW Capacity (kW) 2.7 Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits) Power Factor 0.9 Crest Factor 3:1 Nominal Output Voltage(s) Supported 220V; 230V; 240V Nominal Voltage Details 230V default Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal. Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 3% Output Receptacles (6) C13; (1) C19 Included Output Power Cables Includes three C13 to C14 power cables Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave INPUT Rated input current (Maximum Load) 14.6A 220V; 14.0A 230V; 13.4A 240V Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC Nominal Input Voltage Description 230V factory default UPS Input Connection Type C20 inlet Input Circuit Breakers 20A UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3.1 Recommended Electrical Service 230V Input Phase Single-Phase BATTERY Full Load Runtime (min.) 4.4 min. (2700w) Half Load Runtime (min.) 11.2 min. (1350w) Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP72V15-2U (limit 1); BP72V18-2US (multi-pack compatible); BP72V28RT-3U (multi-pack compatible) Expandable Runtime Description External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details DC System Voltage (VDC) 72 Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge) Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description Online, double-conversion power conditioning Overvoltage Correction 2% output voltage regulation during overvoltages to 280 Undervoltage Correction 2% output voltage regulation during undervoltages to 80V (50% load), 175V (100% load)
1,310,000 IQD
Tripp-Lite Tripp-Lite SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower SMARTINT3000VS
OUTPUT Output Volt Amp Capacity (VA) 3000 Output kVA Capacity (kVA) 3 Output Watt Capacity (Watts) 2250 Output kW Capacity (kW) 2.25 Output Capacity Details 2250W maximum with up to 1 external battery pack; 1500W maximum with 2 or more external battery packs Power Factor 0.75 Nominal Output Voltage(s) Supported 220V; 230V; 240V Nominal Voltage Details 230v nominal inverter output voltage Frequency Compatibility 50 / 60 Hz Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Line Mode) -19% +8% Output Voltage Regulation (Battery Mode) +/- 5% Output Receptacles (8) C13; (1) C19 Included Output Power Cables Includes 3 C13 to C14 output power cables Load Management Receptacles Three switchable two-outlet C13 load banks Output Circuit Breakers 10A (x2) - each breaker protects 4 C13 outlets each, C19 is unbreakered Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave INPUT Rated input current (Maximum Load) 15.4A Nominal Input Voltage(s) Supported 230V AC UPS Input Connection Type C20 inlet UPS Input Connection Description User supplies input cabling with C19 output connection Input Phase Single-Phase BATTERY Full Load Runtime (min.) 4 min. (2250w) Half Load Runtime (min.) 14 min. (1125w) Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible) DC System Voltage (VDC) 48 Battery Recharge Rate (Included Batteries) Less than 4 hours from 10% to 90% (typical, full load discharge) Internal UPS Replacement Battery Cartridge RBC54 Battery Access Battery access door Battery Replacement Description Hot-swappable, user replaceable batteries Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V Overvoltage Correction Input voltages between 245 and 282 are reduced by 12% Undervoltage Correction Input voltages between 177 and 199 are boosted by 14% Severe Undervoltage Correction Input voltages between 151 and 176 are boosted by 30% USER INTERFACE, ALERTS & CONTROLS Switches 2 Switches control off/on power status and alarm-cancel/self-test operation Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 480 UPS AC Suppression Response Time Instantaneous EMI / RFI AC Noise Suppression Yes PHYSICAL Primary Form Factor Tower UPS Power Module Dimensions (hwd, cm) 36.07 x 23.37 x 30.48 UPS Power Module Weight (kg) 27.67 Shipping Dimensions (hwd / cm) 50.55 x 38.35 x 40.89 Shipping Weight (kg) 30.75 Cooling Method Fan UPS Housing Material Polycarbonate Primary UPS Height (mm) 361 Primary UPS Width (mm) 234 Primary UPS Depth (mm) 305 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC Mode Efficiency Rating (100% Load) 94% Audible Noise Audible Noise < 47dBA At Front Side 1 Meter COMMUNICATIONS Communications Interface USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface Network Management Cards SNMPWEBCARD; TLNETCARD; WEBCARDLX Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable 2 USB and 2 DB9 cables included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time 2-4 milliseconds Low Voltage Transfer to Battery Power (Setpoint) 151 High Voltage Transfer to Battery Power (Setpoint) 282 SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Hot swappable batteries CERTIFICATIONS UPS Certifications CE UPS Certification Details CE 62040 WARRANTY Product Warranty Period (International) 2-year limited warranty
950,000 IQD
Tripp-Lite Tripp-Lite SmartOnline 230V 2kVA 1800W On-Line UPS, Tower, Network Card Options, LCD,SUINT2000XLCD
OVERVIEW UPC Code 037332177445 UPS Type Line-Interactive OUTPUT Output Volt Amp Capacity (VA) 1500 Output kVA Capacity (kVA) 1.5 Output Watt Capacity (Watts) 900 Nominal Voltage Details 230V nominal output in battery mode Frequency Compatibility 50 / 60 Hz Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Battery Mode) +/- 5% UPS Output Receptacles (Surge Suppression Only) 6 UPS outlets, 2 surge-only outlets Hot-Swap PDU options PDUBHV10 (2U / 8 C13 outlets) Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave Nominal Output Voltage(s) Supported 220V; 230V; 240V Output Receptacles (8) C13 Individually Controllable Load Banks No INPUT Rated input current (Maximum Load) 9A Nominal Input Voltage(s) Supported 230V AC UPS Input Connection Type C14 inlet Input Circuit Breakers 10A fuse UPS Input Cord Length (ft.) 6 UPS Input Cord Length (m) 1.8 Input Phase Single-Phase BATTERY Half Load Runtime (min.) 10 minutes (450 watts) DC System Voltage (VDC) 24 Battery Recharge Rate (Included Batteries) Less than 8 hours from 10% to 90% Internal UPS Replacement Battery Cartridge RBC51 (requires 2) Expandable Runtime No VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with a correction range from 170V to 280V Overvoltage Correction Input voltages between 247 and 280 are reduced by 15% Undervoltage Correction Input voltages between 170 and 207 are boosted by 18% USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Output load in watts, Battery voltage and Estimated runtime in minutes Switches Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch Audible Alarm Audible alarm indicates power-failure and low-battery conditions SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 455 UPS AC Suppression Response Time Instantaneous UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet EMI / RFI AC Noise Suppression Yes PHYSICAL Cooling Method Fan Installation Form Factors Supported with Included Accessories Tower Primary Form Factor Tower Primary UPS Depth (mm) 394 Primary UPS Height (mm) 203 Primary UPS Width (mm) 146 Shipping Dimensions (hwd / cm) 28.70 x 23.11 x 49.02 Shipping Weight (kg) 12.34 UPS Power Module Dimensions (hwd, cm) 20.32 x 14.60 x 39.37 UPS Power Module Weight (kg) 11.20 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 79 Battery Mode BTU / Hr. (Full Load) 918 AC Mode Efficiency Rating (100% Load) 95% COMMUNICATIONS Communications Interface USB (HID enabled) Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable USB cabling included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time 6 milliseconds Low Voltage Transfer to Battery Power (Setpoint) 170V (factory setting), 175V (medium setting), 180V (narrow setting) High Voltage Transfer to Battery Power (Setpoint) 280V (factory setting), 275V (medium setting), 270V (narrow setting) SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Hot swappable batteries Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS CERTIFICATIONS UPS Certifications CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia) UPS Certification Details EN62040-1, EN62040-2 Class A WARRANTY Product Warranty Period (International) 2-year limited warranty
915,000 IQD
Tripp-Lite Tripp-lite SmartOnline 230V 1kVA 900W On-Line UPS, Tower, Network SUINT1000XLCD
\ Specifications OVERVIEW UPC Code 037332190659 UPS Type On-Line INPUT Rated input current (Maximum Load) 4.9A 220V; 4.7A 230V; 4.5A 240V Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC Nominal Input Voltage Description 230V factory default UPS Input Connection Type C14 inlet Input Circuit Breakers 10A UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3.1 Recommended Electrical Service 230V Input Phase Single-Phase OUTPUT Output Volt Amp Capacity (VA) 1000 Output Capacity (kVA) 1 Output Watt Capacity (Watts) 900 Output kW Capacity (kW) 0.9 Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits) Power Factor 0.9 Crest Factor 3:1 Nominal Voltage Details 230V default Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz; BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 3% Included Output Power Cables Includes two C13 to C14 power cables Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave Nominal Output Voltage(s) Supported 220V; 230V; 240V Output Receptacles (4) C13 Individually Controllable Load Banks No BATTERY Battery Type Valve Regulated Lead Acid (VRLA) Full Load Runtime (min.) 4.8 min. (900w) Half Load Runtime (min.) 12.8 min. (450w) Expandable Battery Runtime Extended runtime supported via optional external battery packs Expandable Runtime Yes Expandable Runtime Description External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details External Battery Pack Compatibility BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible) DC System Voltage (VDC) 24 Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge) VOLTAGE REGULATION Voltage Regulation Description Online, double-conversion power conditioning Overvoltage Correction 2% output voltage regulation during overvoltages to 280 Undervoltage Correction 2% output voltage regulation during undervoltages to 80V (50% load), 175V (100% load)
555,000 IQD