Tripp-Lite SmartOnline 230V 2kVA 1800W On-Line UPS, Tower, Network Card Options, LCD,SUINT2000XLCD
- Tripp-Lite
SKU: SMX2000LCDT
915,000 IQD
OVERVIEW
| UPC Code | 037332177445 |
| UPS Type | Line-Interactive |
OUTPUT
| Output Volt Amp Capacity (VA) | 1500 |
| Output kVA Capacity (kVA) | 1.5 |
| Output Watt Capacity (Watts) | 900 |
| Nominal Voltage Details | 230V nominal output in battery mode |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| UPS Output Receptacles (Surge Suppression Only) | 6 UPS outlets, 2 surge-only outlets |
| Hot-Swap PDU options | PDUBHV10 (2U / 8 C13 outlets) |
| Output AC Waveform (AC Mode) | Sine wave |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
| Output Receptacles | (8) C13 |
| Individually Controllable Load Banks | No |
INPUT
| Rated input current (Maximum Load) | 9A |
| Nominal Input Voltage(s) Supported | 230V AC |
| UPS Input Connection Type | C14 inlet |
| Input Circuit Breakers | 10A fuse |
| UPS Input Cord Length (ft.) | 6 |
| UPS Input Cord Length (m) | 1.8 |
| Input Phase | Single-Phase |
BATTERY
| Half Load Runtime (min.) | 10 minutes (450 watts) |
| DC System Voltage (VDC) | 24 |
| Battery Recharge Rate (Included Batteries) | Less than 8 hours from 10% to 90% |
| Internal UPS Replacement Battery Cartridge | RBC51 (requires 2) |
| Expandable Runtime | No |
VOLTAGE REGULATION
| Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with a correction range from 170V to 280V |
| Overvoltage Correction | Input voltages between 247 and 280 are reduced by 15% |
| Undervoltage Correction | Input voltages between 170 and 207 are boosted by 18% |
USER INTERFACE, ALERTS & CONTROLS
| Front Panel LCD Display | LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Output load in watts, Battery voltage and Estimated runtime in minutes |
| Switches | Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test |
| Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch |
| Audible Alarm | Audible alarm indicates power-failure and low-battery conditions |
SURGE / NOISE SUPPRESSION
| UPS AC Suppression Joule Rating | 455 |
| UPS AC Suppression Response Time | Instantaneous |
| UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
| EMI / RFI AC Noise Suppression | Yes |
PHYSICAL
| Cooling Method | Fan |
| Installation Form Factors Supported with Included Accessories | Tower |
| Primary Form Factor | Tower |
| Primary UPS Depth (mm) | 394 |
| Primary UPS Height (mm) | 203 |
| Primary UPS Width (mm) | 146 |
| Shipping Dimensions (hwd / cm) | 28.70 x 23.11 x 49.02 |
| Shipping Weight (kg) | 12.34 |
| UPS Power Module Dimensions (hwd, cm) | 20.32 x 14.60 x 39.37 |
| UPS Power Module Weight (kg) | 11.20 |
ENVIRONMENTAL
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Relative Humidity | 0 to 95%, non-condensing |
| AC Mode BTU / Hr. (Full Load) | 79 |
| Battery Mode BTU / Hr. (Full Load) | 918 |
| AC Mode Efficiency Rating (100% Load) | 95% |
COMMUNICATIONS
| Communications Interface | USB (HID enabled) |
| Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
| PowerAlert Software | For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Communications Cable | USB cabling included |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER
| Transfer Time | 6 milliseconds |
| Low Voltage Transfer to Battery Power (Setpoint) | 170V (factory setting), 175V (medium setting), 180V (narrow setting) |
| High Voltage Transfer to Battery Power (Setpoint) | 280V (factory setting), 275V (medium setting), 270V (narrow setting) |
SPECIAL FEATURES
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| High Availability UPS Features | Hot swappable batteries |
| Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS |
CERTIFICATIONS
| UPS Certifications | CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia) |
| UPS Certification Details | EN62040-1, EN62040-2 Class A |
WARRANTY
| Product Warranty Period (International) | 2-year limited warranty |