Tripp-Lite SmartOnline 230V 3kVA 2700W On-Line Double-Conversion UPS, Tower, SUINT3000XLCD

Tripp-Lite SmartOnline 230V 3kVA 2700W On-Line Double-Conversion UPS, Tower, SUINT3000XLCD
Tripp-Lite SmartOnline 230V 3kVA 2700W On-Line Double-Conversion UPS, Tower, SUINT3000XLCD

Tripp-Lite SmartOnline 230V 3kVA 2700W On-Line Double-Conversion UPS, Tower, SUINT3000XLCD

Regular price 1,310,000 IQD
/
Tax included. Shipping calculated at checkout.
OUTPUT
Output Volt Amp Capacity (VA) 3000
Output kVA Capacity (kVA) 3
Output Watt Capacity (Watts) 2700
Output kW Capacity (kW) 2.7
Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits)
Power Factor 0.9
Crest Factor 3:1
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Nominal Voltage Details 230V default
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal.
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 3%
Output Receptacles (6) C13; (1) C19
Included Output Power Cables Includes three C13 to C14 power cables
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
INPUT
Rated input current (Maximum Load) 14.6A 220V; 14.0A 230V; 13.4A 240V
Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC
Nominal Input Voltage Description 230V factory default
UPS Input Connection Type C20 inlet
Input Circuit Breakers 20A
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.1
Recommended Electrical Service 230V
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 4.4 min. (2700w)
Half Load Runtime (min.) 11.2 min. (1350w)
Expandable Battery Runtime Extended runtime supported via optional external battery packs
External Battery Pack Compatibility  BP72V15-2U (limit 1);  BP72V18-2US (multi-pack compatible);  BP72V28RT-3U (multi-pack compatible)
Expandable Runtime Description External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details
DC System Voltage (VDC) 72
Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge)
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction 2% output voltage regulation during overvoltages to 280
Undervoltage Correction 2% output voltage regulation during undervoltages to 80V (50% load), 175V (100% load)

Pickup is available at our Baghdad Branch.

Location: Baghdad-62st-near Saj Alreef

Call/Whatsapp: 07834927717

Order is usually ready within 24 hours.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

More from All Products
HP Ink 123
10,500 IQD
HP 652 Black/Tri-color Original Ink Cartridge
20,000 IQD
HP 953 Original Ink Cartidge
from 33,000 IQD
HP Ink 72
125,000 IQD
HP 711 80-ml DesignJet Ink Cartridge
51,000 IQD
HP Toner 415A
from 120,000 IQD
Recently viewed