OUTPUT
Output Volt Amp Capacity (VA) | 3000 |
Output kVA Capacity (kVA) | 3 |
Output Watt Capacity (Watts) | 2700 |
Output kW Capacity (kW) | 2.7 |
Output Capacity Details | OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits) |
Power Factor | 0.9 |
Crest Factor | 3:1 |
Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
Nominal Voltage Details | 230V default |
Frequency Compatibility | 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion |
Frequency Compatibility Details | ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal. |
Output Voltage Regulation (Line Mode) | +/- 2% |
Output Voltage Regulation (Economy Line Mode) | +/- 10% |
Output Voltage Regulation (Battery Mode) | +/- 3% |
Output Receptacles | (6) C13; (1) C19 |
Included Output Power Cables | Includes three C13 to C14 power cables |
Output AC Waveform (AC Mode) | Pure Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT
Rated input current (Maximum Load) | 14.6A 220V; 14.0A 230V; 13.4A 240V |
Nominal Input Voltage(s) Supported | 220V AC; 230V AC; 240V AC |
Nominal Input Voltage Description | 230V factory default |
UPS Input Connection Type | C20 inlet |
Input Circuit Breakers | 20A |
UPS Input Cord Length (ft.) | 10 |
UPS Input Cord Length (m) | 3.1 |
Recommended Electrical Service | 230V |
Input Phase | Single-Phase |
BATTERY
Full Load Runtime (min.) | 4.4 min. (2700w) |
Half Load Runtime (min.) | 11.2 min. (1350w) |
Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
External Battery Pack Compatibility | BP72V15-2U (limit 1); BP72V18-2US (multi-pack compatible); BP72V28RT-3U (multi-pack compatible) |
Expandable Runtime Description | External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details |
DC System Voltage (VDC) | 72 |
Battery Recharge Rate (Included Batteries) | Less than 6 hours from 10% to 90% (typical, full load discharge) |
Expandable Runtime | Yes |
VOLTAGE REGULATION
Voltage Regulation Description | Online, double-conversion power conditioning |
Overvoltage Correction | 2% output voltage regulation during overvoltages to 280 |
Undervoltage Correction | 2% output voltage regulation during undervoltages to 80V (50% load), 175V (100% load) |