UPS And Battries
APC APC Easy UPS SMV 3000VA, Universal Outlet, 230V SMV3000AI-MS - Black
Product Description • Best Value UPS with Battery Backup & Surge Protection for Electronics and Computers • Power Factor : More real output power with 0.7 Pf. • Pure Sinewave : A pure form of sinewave designed to emulate utility power, will support your device upon battery backup • Generator Compatible : Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. • Rugged Metal Construction : Easy UPS SMV is built with resilient sheet metal that rigidly holds and protects critical electrical components. • Automatic Voltage Regulation : Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment. • LCD Display : Intuitive interface provides detailed and accurate information at a glance. • Generous Number of Outlets : 6 battery backup and surge protected outlets are included across all SMV Easy UPS. • Battery Connector : A convenient way to disconnect the battery for transport. • Communication Ports : USB and serial ports for UPS management. • Safety Agency Approved : Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. What's in the box • 1 x APC Easy UPS SMV 3000VA, Universal Outlet, 230V SMV3000AI-MS - Black • 1 x Documentation CD • 1 x USB cable • 1 x User manual About Us SNS Network, a MSC Status Company was established in 1998, incorporated in 2000 and the head office is located in Ipoh, Perak. We have setup three offices strategically located at the Major cities of Malaysia; Perai (Penang), Ipoh (Perak), and Petaling Jaya (Selangor). SNS Network is also the first company to be awarded as Intel® Authorized Solution Provider (IASP) in Perak. Besides being awarded by Intel as Intel® Premier Provider beginning from 2000 until now, we are further recognized as Intel® Certified Solutions Consultant and Intel® Certified Integration Specialist. We are also being recognized by Microsoft® as Microsoft® Gold Certified Partner with qualified Microsoft® Certified System Engineer expertise. With more than 10 years of outstanding technical expertise and experience, SNS Network delivers proven, flexible solutions that can enable our clients to become more adaptable, responsive, and profitable. We assist our clients in maximizing their information resources and enhancing their competitive advantage. As a leading technology provider with inherent strengths in the provision of scalable ICT solutions, SNS Network is geared to harness its domain-driven and knowledge-based expertise for the myriad of industries that we serves. Today ever changing market and intense competition has forced organizations to adapt and response quickly. At SNS, we understand that no two companies or industries are alike. Our solutions are designed and tailored to suit the industry, organization’s size, and the ultimate objectives.
955,000 IQD
APC APC Easy UPS SMV 1500VA, Universal Outlet, 230V
Output power capacity 700Watts / 1.0kVA Max Configurable Power (Watts) 700Watts / 1.0kVA Nominal Output Voltage 230V Output Frequency (not synced) 50/60 Hz +/-1 Hz Load Crest Factor 3 : 1 Topology Line Interactive Waveform type Sine wave Transfer Time 2ms typical Input Nominal Input Voltage 230V Input frequency 45 - 65 Hz (auto sensing) Input Connections IEC-320 C14 Input voltage range for main operations 160 - 295V Number of Power Cords 1 Other Input Voltages 220, 240 Batteries & Runtime Battery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof Typical recharge time 4hour(s) Expected Battery Life (years) 3 - 5 Battery Volt-Amp-Hour Capacity 150 Runtime View Runtime Graph View Runtime Chart Efficiency View Efficiency Graph Communications & Management Interface Port(s) USB Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm Physical Maximum Height 220MM, 22.0CM Maximum Width 160MM, 16.0CM Maximum Depth 410MM, 41.0CM Net Weight 13.6KG Shipping weight 16.6KG Shipping Height 339MM, 33.9CM Shipping Width 272MM, 27.2CM Shipping Depth 508MM, 50.8CM Environmental Operating Temperature 0 - 40 °C Operating Relative Humidity 0 - 90 % Operating Elevation 0-999.9meters Storage Temperature -10 - 40 °C Storage Relative Humidity 0 - 95 % Storage Elevation 0-3000meters Audible noise at 1 meter from surface of unit 45.0dBA Conformance Approvals CE Standard warranty 2 years repair or replace
545,000 IQD
Tripp-Lite TRIPP LITE SmartPro 230V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Network Card Options, USB, DB9 Serial
UPC Code 037332119780 UPS Type Line-Interactive OUTPUT Output Volt Amp Capacity (VA) 1500 Output kVA Capacity (kVA) 1.5 Output Watt Capacity (Watts) 940 Nominal Voltage Details 230V nominal output in battery mode Frequency Compatibility 50 / 60 Hz Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Line Mode) -18%, +8% Output Voltage Regulation (Battery Mode) +/- 5% Included Output Power Cables Includes 2 C13 to C14 output power cables Hot-Swap PDU options PDUBHV10 (2U / 8 C13 outlets) Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave Nominal Output Voltage(s) Supported 220V; 230V; 240V Output Receptacles (8) C13 Individually Controllable Load Banks No INPUT Rated input current (Maximum Load) 5A Nominal Input Voltage(s) Supported 230V AC UPS Input Connection Type C14 inlet UPS Input Connection Description Attached 15cm line cord with C14 inlet. The C14 inlet accepts user-supplied AC power cord with country-specific plug. UPS Input Cord Length (ft.) 0.5 UPS Input Cord Length (m) 0.2 Input Phase Single-Phase BATTERY Full Load Runtime (min.) 4.5 min. (940w) Half Load Runtime (min.) 13 min. (470w) Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible) DC System Voltage (VDC) 24 Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90% Internal UPS Replacement Battery Cartridge RBC51 (quantity 2) Battery Access Battery access door Battery Replacement Description Hot-swappable, user replaceable batteries Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151 to 282 Overvoltage Correction Input voltages between 245 and 282 are reduced by 12% Undervoltage Correction Input voltages between 177 and 199 are boosted by 14% Severe Undervoltage Correction Input voltages between 151 and 176 are boosted by 30% USER INTERFACE, ALERTS & CONTROLS Switches 2 Switches control off/on power status and alarm-cancel/self-test operation Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status Audible Alarm Audible alarm indicates power-failure and low-battery conditions LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 340 UPS AC Suppression Response Time Instantaneous UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet EMI / RFI AC Noise Suppression Yes PHYSICAL Installation Form Factors Supported with Included Accessories Tower Installation Form Factors Supported with Optional Accessories Wallmount (UPSWM - tower mounting kit) Primary Form Factor Tower Primary UPS Depth (mm) 191 Primary UPS Height (mm) 300 Primary UPS Width (mm) 183 Shipping Dimensions (hwd / cm) 39.62 x 26.42 x 27.43 Shipping Weight (kg) 14.74 UPS Housing Material Polycarbonate UPS Power Module Dimensions (hwd, cm) 29.97 x 18.29 x 19.05 UPS Power Module Weight (kg) 14.51 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 99 Battery Mode BTU / Hr. (Full Load) 657 AC Mode Efficiency Rating (100% Load) 97% COMMUNICATIONS Communications Interface USB PowerAlert Software For local monitoring via the UPS’s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable USB interface cable included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time 2-4 milliseconds Low Voltage Transfer to Battery Power (Setpoint) 151 High Voltage Transfer to Battery Power (Setpoint) 282 SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Hot swappable batteries Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS CERTIFICATIONS UPS Certifications Tested to UL1778 (USA); CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina) UPS Certification Details CE 62040 WARRANTY Product Warranty Period (International) 2-year limited warranty
480,000 IQD
Tripp-Lite Tripp-Lite SmartOnline 208/230V 3kVA 2.7kW Double-Conversion UPS, 2U Rack/Tower SUINT3000LCD2U
OUTPUT Output Volt Amp Capacity (VA) 3000 Output kVA Capacity (kVA) 3 Output Watt Capacity (Watts) 2700 Output kW Capacity (kW) 2.7 Output Capacity Details DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1890 watts for 208/220/230/240V output voltages; Max output is reduced to 2160W at 200V output voltage in all operating modes OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits). Power Factor 0.9 Crest Factor 3:1 Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V Nominal Voltage Details Nominal output voltage is user configured on first power-on Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 2% Output Receptacles (8) C13; (2) C19 Included Output Power Cables Includes 2 C13 to C14 and 1 C19 to C20 power cables Load Management Receptacles Two switchable 4 outlet load banks (3 C13 and 1 C19 per bank) Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave INPUT Rated input current (Maximum Load) 14.97A Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC UPS Input Connection Type C20 inlet Input Phase Single-Phase BATTERY Full Load Runtime (min.) 5 min. (2700w) Half Load Runtime (min.) 13.5 min. (1350w) Expandable Battery Runtime Supports extended runtime with optional external battery packs External Battery Pack Compatibility BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) DC System Voltage (VDC) 72 Battery Recharge Rate (Included Batteries) 3.0 hours from 10% to 90% (typical, full load discharge) Internal UPS Replacement Battery Cartridge RBC72S Battery Access Front panel battery access door Battery Replacement Description Hot-swappable, replaceable batteries Expandable Runtime Yes
1,875,000 IQD
Tripp-Lite Tripp-Lite SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, SMX3000XLRT2UA
3kVA / 3000VA / 2700W line interactive 2U rack/tower UPS, Sine Wave Extended runtime options up to 2700W, 0.9 Power Factor, Interactive LCD interface 98% line-mode efficiency, 2 switched load banks, 4 post mounting kit USB, RS232, EPO and slot for network management card options230V C20 inlet, 8 C13 & 1 C19 outlets Add optional WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature 2-year limited warranty
1,000,000 IQD
Tripp-Lite Tripp-Lite SmartOnline 230V 3kVA 2700W On-Line Double-Conversion UPS, Tower, SUINT3000XLCD
OUTPUT Output Volt Amp Capacity (VA) 3000 Output kVA Capacity (kVA) 3 Output Watt Capacity (Watts) 2700 Output kW Capacity (kW) 2.7 Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits) Power Factor 0.9 Crest Factor 3:1 Nominal Output Voltage(s) Supported 220V; 230V; 240V Nominal Voltage Details 230V default Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal. Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 3% Output Receptacles (6) C13; (1) C19 Included Output Power Cables Includes three C13 to C14 power cables Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave INPUT Rated input current (Maximum Load) 14.6A 220V; 14.0A 230V; 13.4A 240V Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC Nominal Input Voltage Description 230V factory default UPS Input Connection Type C20 inlet Input Circuit Breakers 20A UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3.1 Recommended Electrical Service 230V Input Phase Single-Phase BATTERY Full Load Runtime (min.) 4.4 min. (2700w) Half Load Runtime (min.) 11.2 min. (1350w) Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP72V15-2U (limit 1); BP72V18-2US (multi-pack compatible); BP72V28RT-3U (multi-pack compatible) Expandable Runtime Description External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details DC System Voltage (VDC) 72 Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge) Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description Online, double-conversion power conditioning Overvoltage Correction 2% output voltage regulation during overvoltages to 280 Undervoltage Correction 2% output voltage regulation during undervoltages to 80V (50% load), 175V (100% load)
1,310,000 IQD
Tripp-Lite Tripp-Lite SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower SMARTINT3000VS
OUTPUT Output Volt Amp Capacity (VA) 3000 Output kVA Capacity (kVA) 3 Output Watt Capacity (Watts) 2250 Output kW Capacity (kW) 2.25 Output Capacity Details 2250W maximum with up to 1 external battery pack; 1500W maximum with 2 or more external battery packs Power Factor 0.75 Nominal Output Voltage(s) Supported 220V; 230V; 240V Nominal Voltage Details 230v nominal inverter output voltage Frequency Compatibility 50 / 60 Hz Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Line Mode) -19% +8% Output Voltage Regulation (Battery Mode) +/- 5% Output Receptacles (8) C13; (1) C19 Included Output Power Cables Includes 3 C13 to C14 output power cables Load Management Receptacles Three switchable two-outlet C13 load banks Output Circuit Breakers 10A (x2) - each breaker protects 4 C13 outlets each, C19 is unbreakered Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave INPUT Rated input current (Maximum Load) 15.4A Nominal Input Voltage(s) Supported 230V AC UPS Input Connection Type C20 inlet UPS Input Connection Description User supplies input cabling with C19 output connection Input Phase Single-Phase BATTERY Full Load Runtime (min.) 4 min. (2250w) Half Load Runtime (min.) 14 min. (1125w) Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible) DC System Voltage (VDC) 48 Battery Recharge Rate (Included Batteries) Less than 4 hours from 10% to 90% (typical, full load discharge) Internal UPS Replacement Battery Cartridge RBC54 Battery Access Battery access door Battery Replacement Description Hot-swappable, user replaceable batteries Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V Overvoltage Correction Input voltages between 245 and 282 are reduced by 12% Undervoltage Correction Input voltages between 177 and 199 are boosted by 14% Severe Undervoltage Correction Input voltages between 151 and 176 are boosted by 30% USER INTERFACE, ALERTS & CONTROLS Switches 2 Switches control off/on power status and alarm-cancel/self-test operation Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 480 UPS AC Suppression Response Time Instantaneous EMI / RFI AC Noise Suppression Yes PHYSICAL Primary Form Factor Tower UPS Power Module Dimensions (hwd, cm) 36.07 x 23.37 x 30.48 UPS Power Module Weight (kg) 27.67 Shipping Dimensions (hwd / cm) 50.55 x 38.35 x 40.89 Shipping Weight (kg) 30.75 Cooling Method Fan UPS Housing Material Polycarbonate Primary UPS Height (mm) 361 Primary UPS Width (mm) 234 Primary UPS Depth (mm) 305 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC Mode Efficiency Rating (100% Load) 94% Audible Noise Audible Noise < 47dBA At Front Side 1 Meter COMMUNICATIONS Communications Interface USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface Network Management Cards SNMPWEBCARD; TLNETCARD; WEBCARDLX Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable 2 USB and 2 DB9 cables included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time 2-4 milliseconds Low Voltage Transfer to Battery Power (Setpoint) 151 High Voltage Transfer to Battery Power (Setpoint) 282 SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Hot swappable batteries CERTIFICATIONS UPS Certifications CE UPS Certification Details CE 62040 WARRANTY Product Warranty Period (International) 2-year limited warranty
950,000 IQD
Tripp-Lite Tripp-Lite SmartOnline 230V 2kVA 1800W On-Line UPS, Tower, Network Card Options, LCD,SUINT2000XLCD
OVERVIEW UPC Code 037332177445 UPS Type Line-Interactive OUTPUT Output Volt Amp Capacity (VA) 1500 Output kVA Capacity (kVA) 1.5 Output Watt Capacity (Watts) 900 Nominal Voltage Details 230V nominal output in battery mode Frequency Compatibility 50 / 60 Hz Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Battery Mode) +/- 5% UPS Output Receptacles (Surge Suppression Only) 6 UPS outlets, 2 surge-only outlets Hot-Swap PDU options PDUBHV10 (2U / 8 C13 outlets) Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave Nominal Output Voltage(s) Supported 220V; 230V; 240V Output Receptacles (8) C13 Individually Controllable Load Banks No INPUT Rated input current (Maximum Load) 9A Nominal Input Voltage(s) Supported 230V AC UPS Input Connection Type C14 inlet Input Circuit Breakers 10A fuse UPS Input Cord Length (ft.) 6 UPS Input Cord Length (m) 1.8 Input Phase Single-Phase BATTERY Half Load Runtime (min.) 10 minutes (450 watts) DC System Voltage (VDC) 24 Battery Recharge Rate (Included Batteries) Less than 8 hours from 10% to 90% Internal UPS Replacement Battery Cartridge RBC51 (requires 2) Expandable Runtime No VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with a correction range from 170V to 280V Overvoltage Correction Input voltages between 247 and 280 are reduced by 15% Undervoltage Correction Input voltages between 170 and 207 are boosted by 18% USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Output load in watts, Battery voltage and Estimated runtime in minutes Switches Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch Audible Alarm Audible alarm indicates power-failure and low-battery conditions SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 455 UPS AC Suppression Response Time Instantaneous UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet EMI / RFI AC Noise Suppression Yes PHYSICAL Cooling Method Fan Installation Form Factors Supported with Included Accessories Tower Primary Form Factor Tower Primary UPS Depth (mm) 394 Primary UPS Height (mm) 203 Primary UPS Width (mm) 146 Shipping Dimensions (hwd / cm) 28.70 x 23.11 x 49.02 Shipping Weight (kg) 12.34 UPS Power Module Dimensions (hwd, cm) 20.32 x 14.60 x 39.37 UPS Power Module Weight (kg) 11.20 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 79 Battery Mode BTU / Hr. (Full Load) 918 AC Mode Efficiency Rating (100% Load) 95% COMMUNICATIONS Communications Interface USB (HID enabled) Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable USB cabling included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time 6 milliseconds Low Voltage Transfer to Battery Power (Setpoint) 170V (factory setting), 175V (medium setting), 180V (narrow setting) High Voltage Transfer to Battery Power (Setpoint) 280V (factory setting), 275V (medium setting), 270V (narrow setting) SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Hot swappable batteries Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS CERTIFICATIONS UPS Certifications CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia) UPS Certification Details EN62040-1, EN62040-2 Class A WARRANTY Product Warranty Period (International) 2-year limited warranty
915,000 IQD
Tripp-Lite Tripp-lite SmartOnline 230V 1kVA 900W On-Line UPS, Tower, Network SUINT1000XLCD
\ Specifications OVERVIEW UPC Code 037332190659 UPS Type On-Line INPUT Rated input current (Maximum Load) 4.9A 220V; 4.7A 230V; 4.5A 240V Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC Nominal Input Voltage Description 230V factory default UPS Input Connection Type C14 inlet Input Circuit Breakers 10A UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3.1 Recommended Electrical Service 230V Input Phase Single-Phase OUTPUT Output Volt Amp Capacity (VA) 1000 Output Capacity (kVA) 1 Output Watt Capacity (Watts) 900 Output kW Capacity (kW) 0.9 Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits) Power Factor 0.9 Crest Factor 3:1 Nominal Voltage Details 230V default Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz; BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 3% Included Output Power Cables Includes two C13 to C14 power cables Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave Nominal Output Voltage(s) Supported 220V; 230V; 240V Output Receptacles (4) C13 Individually Controllable Load Banks No BATTERY Battery Type Valve Regulated Lead Acid (VRLA) Full Load Runtime (min.) 4.8 min. (900w) Half Load Runtime (min.) 12.8 min. (450w) Expandable Battery Runtime Extended runtime supported via optional external battery packs Expandable Runtime Yes Expandable Runtime Description External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details External Battery Pack Compatibility BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible) DC System Voltage (VDC) 24 Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge) VOLTAGE REGULATION Voltage Regulation Description Online, double-conversion power conditioning Overvoltage Correction 2% output voltage regulation during overvoltages to 280 Undervoltage Correction 2% output voltage regulation during undervoltages to 80V (50% load), 175V (100% load)
555,000 IQD
Tripp-Lite Tripp-Lite AVR Series 230V 750VA
OUTPUT Output Volt Amp Capacity (VA) 750 Output Watt Capacity (Watts) 450 Nominal Output Voltage(s) Supported 220V; 230V; 240V Nominal Voltage Details 230V nominal output in battery mode Frequency Compatibility 50 / 60 Hz Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Line Mode) +8%, -21% Output Voltage Regulation (Battery Mode) +/- 5% Output Receptacles (8) CEE7/7 UPS Output Receptacles (Surge Suppression Only) 4 UPS outlets, 4 surge-only outlets Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave INPUT Rated input current (Maximum Load) 10A Nominal Input Voltage(s) Supported 230V AC UPS Input Connection Type CEE 7/7 Schuko UPS Input Cord Length (ft.) 6 UPS Input Cord Length (m) 1.8 Input Phase Single-Phase BATTERY Full Load Runtime (min.) 2.6 min. (450w) Half Load Runtime (min.) 8.6 min. (225w) DC System Voltage (VDC) 12 Battery Recharge Rate (Included Batteries) Less than 16 hours from 10% to 90% Internal UPS Replacement Battery Cartridge RBC51 (QTY 1) Battery Access Battery access door Battery Replacement Description Hot-swappable, user replaceable batteries Expandable Runtime No VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 159 to 282VAC Overvoltage Correction Input voltages between 245 and 282 are reduced by 12% Undervoltage Correction Input voltages between 159 and 205 are boosted by 14% USER INTERFACE, ALERTS & CONTROLS Switches Combination switch controls on/off power status and self-test operation Audible Alarm Audible alarm indicates power-failure, overload and low-battert status LED Indicators 2 LEDs indicate off/on power status and overload/low-battery status SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 575 UPS AC Suppression Response Time Instantaneous UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out) EMI / RFI AC Noise Suppression Yes PHYSICAL Installation Form Factors Supported with Included Accessories Ultra-compact desktop; Wallmount Primary Form Factor Desktop UPS Power Module Dimensions (hwd, cm) 12.01 x 27.94 x 15.24 UPS Power Module Weight (kg) 5.99 Shipping Dimensions (hwd / cm) 23.37 x 36.50 x 23.37 Shipping Weight (kg) 6.53 UPS Housing Material ABS Primary UPS Height (mm) 120 Primary UPS Width (mm) 279 Primary UPS Depth (mm) 152 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius. Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. Relative Humidity 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 16 Battery Mode BTU / Hr. (Full Load) 408 AC Mode Efficiency Rating (100% Load) 99% COMMUNICATIONS Communications Interface USB PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable USB interface cable included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications Network UPS Tools Compatibility NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite LINE / BATTERY TRANSFER Transfer Time 4 milliseconds (line to battery mode) / 1 millisecond (battery to line mode) Low Voltage Transfer to Battery Power (Setpoint) 159 High Voltage Transfer to Battery Power (Setpoint) 282 SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Hot swappable batteries Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS CERTIFICATIONS UPS Certifications CE; Meets FCC Part 15 Category B (EMI); ROHS (Restriction of Hazardous Substances) UPS Certification Details IEC 62040, IEC 60950, EN 62040 WARRANTY Product Warranty Period (International) 2-year limited warranty
130,000 IQD