Specifications

OVERVIEW
UPC Code 037332190659
UPS Type On-Line
OUTPUT
Output Volt Amp Capacity (VA) 1000
Output kVA Capacity (kVA) 1
Output Watt Capacity (Watts) 900
Output kW Capacity (kW) 0.9
Power Factor   0.9
Crest Factor   3:1
Nominal Voltage Details 230V default
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz; BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 3%
Included Output Power Cables Includes two C13 to C14 power cables
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits)
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Output Receptacles (4) C13
Individually Controllable Load Banks   No
INPUT
Rated input current (Maximum Load) 4.9A 220V; 4.7A 230V; 4.5A 240V
Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC
Nominal Input Voltage Description 230V factory default
UPS Input Connection Type C14 inlet
Input Circuit Breakers 10A
UPS Input Cord Length (ft.) 10
UPS Input Cord Length (m) 3.1
Recommended Electrical Service 230V
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.)   4.8 min. (900w)
Half Load Runtime (min.)   12.8 min. (450w)
Expandable Battery Runtime Extended runtime supported via optional external battery packs
External Battery Pack Compatibility    BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)
Expandable Runtime Description External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details
DC System Voltage (VDC) 24
Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge)
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction   2% output voltage regulation during overvoltages to 280
Undervoltage Correction   2% output voltage regulation during undervoltages to 80V (50% load), 175V (100% load)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional information
Switches ON switch supports inverter-on, battery-test, alarm-off and enter functions; OFF switch supports inverter-off and fault-clear functions; SETUP switch enables scroll-down and enter setup-mode functions
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 425
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression   Yes
PHYSICAL
Cooling Method Fan
Primary Form Factor Tower
Primary UPS Depth (mm) 320
Primary UPS Height (mm) 226
Primary UPS Width (mm) 145
Shipping Dimensions (hwd / cm) 34.04 x 24.13 x 44.70
Shipping Weight (kg) 11.61
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, cm) 22.61 x 14.48 x 32.00
UPS Power Module Weight (kg) 9.66
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)   312
AC Economy Mode BTU / Hr. (Full Load) 145
Battery Mode BTU / Hr. (Full Load)   542
AC Mode Efficiency Rating (100% Load) 91%
AC Economy Mode Efficiency Rating (100% Load) 95%
Operating Elevation (ft.) 0-3000ft
Audible Noise < 50 dB at front side 1m
Operating Elevation (m) 0-1000m
COMMUNICATIONS
Communications Interface DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled)
Network Management Cards SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD 
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable USB and DB9 cabling included
LINE / BATTERY TRANSFER
Transfer Time   Zero transfer time (0 ms.)
Low Voltage Transfer to Battery Power (Setpoint) 80V (<50% load), 175V (100% load)
High Voltage Transfer to Battery Power (Setpoint) 280
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Automatic inverter bypass; Hot swappable batteries
Green Energy-Saving Features High efficiency economy mode operation
CERTIFICATIONS
UPS Certifications CE
UPS Certification Details IEC 62040-1;2008+A1:2013; EN62040-2:2006; ESD:IEC61000-4-2:LEVEL 4, RS:IEC61000-4-3:LEVEL 3, EFT:IEC61000-4-4:LEVEL 2, SURGE: IEC61000-4-5:LEVEL 2, CS:IEC61000-4-6:LEVEL 3, CONDUCTED MAGNETIC FIELD: IEC61000-4-8:LEVEL 4
WARRANTY