Tripp-Lite SmartOnline 200-240V 10kVA 9kW Double-Conversion UPS, 6U

Description

UTPUT
Output Volt Amp Capacity (VA) 10000
Output kVA Capacity (kVA) 10
Output Watt Capacity (Watts) 9000
Output kW Capacity (kW) 9
Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
Power Factor 0,9
Crest Factor 3:1
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
Nominal Voltage Details Voltage selection via front panel LCD interface
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating); Output frequency regulation +/- 0.05Hz (free running)
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 2%
Output Receptacles Hardwire
Output Receptacle Details Supports North American 208/240V* output (L1,L2,G) and International 230/220/240V (L,N,PE) hardwire output; *For 120V output with 208/240V (L1,L2,G) input wiring, use optional SU6000XFMR2U transformer
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
INPUT
Rated input current (Maximum Load) 56.1A (200V), 54A (208V), 51A (220V), 48.8A (230V), 46.8A (240V)
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection Type Hardwire
UPS Input Connection Description Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring
Recommended Electrical Service 60A
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 4.3 min. (9000w)
Half Load Runtime (min.) 12.5 min. (4500w)
Expandable Battery Runtime Supports extended runtime with optional external battery packs
External Battery Pack Compatibility BP240V10RT3U;  BP240V787C-1PH 
DC System Voltage (VDC) 240
Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge)
Battery Replacement Description Hot-swappable, user replaceable external battery packs
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description 2% output voltage regulation in standard online, double-conversion mode
Overvoltage Correction Corrects overvoltages up to 300V
Undervoltage Correction Corrects undervoltages as low as 100V
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
Alarm Cancel Operation Alarm cancel switch
Audible Alarm Unique audible alarms for all major UPS, environmental and power conditions (see manual)
LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
SURGE / NOISE SUPPRESSION
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Included Mounting Accessory Description 2 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included
Installation Form Factors Supported with Optional Accessories 2 post rackmount (2POSTRMKITHD)
Optional Mounting Accessory Notes 2 sets of 2POSTRMKITHD required for 2 post rackmount installation of all included components
Primary Form Factor Rackmount
UPS Power Module Dimensions (hwd, cm) 13.06 x 44.45 x 65.58
Rack Height (U Spaces) 6
Maximum Device Depth (cm) 82.55
Minimum Required Rack Depth (cm) 95.25
UPS Power Module Weight (kg) 19.50
UPS Dimensions Details Includes 3U UPS/power module, 3U external battery pack plus SUPDMB710HW PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed
Included Battery Pack Weight (kg) 71.99
Shipping Dimensions (hwd / cm) 78.74 x 66.04 x 104.14
Shipping Weight (kg) 148.58
Cooling Method Fan
UPS Housing Material Steel
Maximum Device Depth (mm) 826
Primary UPS Height (mm) 131
Primary UPS Width (mm) 445
Primary UPS Depth (mm) 656
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 3415
AC Economy Mode BTU / Hr. (Full Load) 1280
Battery Mode BTU / Hr. (Full Load) 4593
AC Mode Efficiency Rating (100% Load) 91%
AC Economy Mode Efficiency Rating (100% Load) 96%
Operating Elevation (ft.) 0-3000m (0 to 10,000 ft.)
Audible Noise 60 dBA at front side 1 meter
Operating Elevation (m) 0-3000 m
COMMUNICATIONS
Communications Interface USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network Management Cards SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD;  RELAYIOCARD 
Network Monitoring Port Description Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable USB, DB9 serial and EPO cables included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode
Transfer Time (Economy Mode) 8 ms. typical power failure response in optional economy mode
Low Voltage Transfer to Battery Power (Setpoint) 100V
High Voltage Transfer to Battery Power (Setpoint) 300V
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Economy Mode Operation Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.
High Availability UPS Features Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
Green Energy-Saving Features High efficiency economy mode operation; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); CE; Meets FCC Part 15 Category A (EMI)
UPS Certification Details IEC 61000-4-5 1995 B Surge Immunity
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance 
Product form

UTPUT Output Volt Amp Capacity (VA) 10000 Output kVA Capacity (kVA) 10 Output Watt Capacity (Watts) 9000 Output kW Capacity... Read more

Free pickup in our shop(s)

SKU: SU10KRT3UHV

3 in stock

4,000,000 IQD Incl. VAT

    • 1 Year Warranty

    Description

    UTPUT
    Output Volt Amp Capacity (VA) 10000
    Output kVA Capacity (kVA) 10
    Output Watt Capacity (Watts) 9000
    Output kW Capacity (kW) 9
    Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
    Power Factor 0,9
    Crest Factor 3:1
    Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
    Nominal Voltage Details Voltage selection via front panel LCD interface
    Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
    Frequency Compatibility Details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating); Output frequency regulation +/- 0.05Hz (free running)
    Output Voltage Regulation (Line Mode) +/- 2%
    Output Voltage Regulation (Economy Line Mode) +/- 10%
    Output Voltage Regulation (Battery Mode) +/- 2%
    Output Receptacles Hardwire
    Output Receptacle Details Supports North American 208/240V* output (L1,L2,G) and International 230/220/240V (L,N,PE) hardwire output; *For 120V output with 208/240V (L1,L2,G) input wiring, use optional SU6000XFMR2U transformer
    Output AC Waveform (AC Mode) Pure Sine wave
    Output AC Waveform (Battery Mode) Pure Sine wave
    INPUT
    Rated input current (Maximum Load) 56.1A (200V), 54A (208V), 51A (220V), 48.8A (230V), 46.8A (240V)
    Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
    UPS Input Connection Type Hardwire
    UPS Input Connection Description Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring
    Recommended Electrical Service 60A
    Input Phase Single-Phase
    BATTERY
    Full Load Runtime (min.) 4.3 min. (9000w)
    Half Load Runtime (min.) 12.5 min. (4500w)
    Expandable Battery Runtime Supports extended runtime with optional external battery packs
    External Battery Pack Compatibility BP240V10RT3U;  BP240V787C-1PH 
    DC System Voltage (VDC) 240
    Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge)
    Battery Replacement Description Hot-swappable, user replaceable external battery packs
    Expandable Runtime Yes
    VOLTAGE REGULATION
    Voltage Regulation Description 2% output voltage regulation in standard online, double-conversion mode
    Overvoltage Correction Corrects overvoltages up to 300V
    Undervoltage Correction Corrects undervoltages as low as 100V
    USER INTERFACE, ALERTS & CONTROLS
    Front Panel LCD Display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)
    Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
    Alarm Cancel Operation Alarm cancel switch
    Audible Alarm Unique audible alarms for all major UPS, environmental and power conditions (see manual)
    LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
    SURGE / NOISE SUPPRESSION
    UPS AC Suppression Response Time Instantaneous
    EMI / RFI AC Noise Suppression Yes
    PHYSICAL
    Included Mounting Accessory Description 2 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included
    Installation Form Factors Supported with Optional Accessories 2 post rackmount (2POSTRMKITHD)
    Optional Mounting Accessory Notes 2 sets of 2POSTRMKITHD required for 2 post rackmount installation of all included components
    Primary Form Factor Rackmount
    UPS Power Module Dimensions (hwd, cm) 13.06 x 44.45 x 65.58
    Rack Height (U Spaces) 6
    Maximum Device Depth (cm) 82.55
    Minimum Required Rack Depth (cm) 95.25
    UPS Power Module Weight (kg) 19.50
    UPS Dimensions Details Includes 3U UPS/power module, 3U external battery pack plus SUPDMB710HW PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed
    Included Battery Pack Weight (kg) 71.99
    Shipping Dimensions (hwd / cm) 78.74 x 66.04 x 104.14
    Shipping Weight (kg) 148.58
    Cooling Method Fan
    UPS Housing Material Steel
    Maximum Device Depth (mm) 826
    Primary UPS Height (mm) 131
    Primary UPS Width (mm) 445
    Primary UPS Depth (mm) 656
    ENVIRONMENTAL
    Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
    Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
    Relative Humidity 0 to 95%, non-condensing
    AC Mode BTU / Hr. (Full Load) 3415
    AC Economy Mode BTU / Hr. (Full Load) 1280
    Battery Mode BTU / Hr. (Full Load) 4593
    AC Mode Efficiency Rating (100% Load) 91%
    AC Economy Mode Efficiency Rating (100% Load) 96%
    Operating Elevation (ft.) 0-3000m (0 to 10,000 ft.)
    Audible Noise 60 dBA at front side 1 meter
    Operating Elevation (m) 0-3000 m
    COMMUNICATIONS
    Communications Interface USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
    Network Management Cards SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD;  RELAYIOCARD 
    Network Monitoring Port Description Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
    PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
    Communications Cable USB, DB9 serial and EPO cables included
    WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
    LINE / BATTERY TRANSFER
    Transfer Time No transfer time (0 ms.) in online, double-conversion mode
    Transfer Time (Economy Mode) 8 ms. typical power failure response in optional economy mode
    Low Voltage Transfer to Battery Power (Setpoint) 100V
    High Voltage Transfer to Battery Power (Setpoint) 300V
    SPECIAL FEATURES
    Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
    Economy Mode Operation Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.
    High Availability UPS Features Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch
    Green Energy-Saving Features High efficiency economy mode operation; Schedulable daily hours of economy mode operation
    CERTIFICATIONS
    UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); CE; Meets FCC Part 15 Category A (EMI)
    UPS Certification Details IEC 61000-4-5 1995 B Surge Immunity
    WARRANTY
    Product Warranty Period (Worldwide) 2-year limited warranty
    Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance 

    Reviews

    Tripp-Lite SmartOnline 200-240V 10kVA 9kW Double-Conversion UPS, 6U

    Tripp-Lite SmartOnline 200-240V 10kVA 9kW Double-Conversion UPS, 6U

    0 out of 5 stars

    This product has no reviews yet

    Recently viewed products

    Footer image

    © 2024 AL FARAH STORE, Powered by Shopify

      Login

      Forgot your password?

      Don't have an account yet?
      Create account