Tripp-Lite SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower SMARTINT3000VS

Tripp-Lite SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower  SMARTINT3000VS
Tripp-Lite SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower  SMARTINT3000VS

Tripp-Lite SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower SMARTINT3000VS

Regular price 950,000 IQD
/
Tax included. Shipping calculated at checkout.
OUTPUT
Output Volt Amp Capacity (VA) 3000
Output kVA Capacity (kVA) 3
Output Watt Capacity (Watts) 2250
Output kW Capacity (kW) 2.25
Output Capacity Details 2250W maximum with up to 1 external battery pack; 1500W maximum with 2 or more external battery packs
Power Factor 0.75
Nominal Output Voltage(s) Supported 220V; 230V; 240V
Nominal Voltage Details 230v nominal inverter output voltage
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) -19% +8%
Output Voltage Regulation (Battery Mode) +/- 5%
Output Receptacles (8) C13; (1) C19
Included Output Power Cables Includes 3 C13 to C14 output power cables
Load Management Receptacles Three switchable two-outlet C13 load banks
Output Circuit Breakers 10A (x2) - each breaker protects 4 C13 outlets each, C19 is unbreakered
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
INPUT
Rated input current (Maximum Load) 15.4A
Nominal Input Voltage(s) Supported 230V AC
UPS Input Connection Type C20 inlet
UPS Input Connection Description User supplies input cabling with C19 output connection
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 4 min. (2250w)
Half Load Runtime (min.) 14 min. (1125w)
Expandable Battery Runtime Extended runtime supported via optional external battery packs
External Battery Pack Compatibility  BP48V24-2U (limit 1);  BP48V60RT-3U (multi-pack compatible);  BP48V27-2US (multi-pack compatible)
DC System Voltage (VDC) 48
Battery Recharge Rate (Included Batteries) Less than 4 hours from 10% to 90% (typical, full load discharge)
Internal UPS Replacement Battery Cartridge  RBC54 
Battery Access Battery access door
Battery Replacement Description Hot-swappable, user replaceable batteries
Expandable Runtime Yes
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V
Overvoltage Correction Input voltages between 245 and 282 are reduced by 12%
Undervoltage Correction Input voltages between 177 and 199 are boosted by 14%
Severe Undervoltage Correction Input voltages between 151 and 176 are boosted by 30%
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions
LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 480
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Primary Form Factor Tower
UPS Power Module Dimensions (hwd, cm) 36.07 x 23.37 x 30.48
UPS Power Module Weight (kg) 27.67
Shipping Dimensions (hwd / cm) 50.55 x 38.35 x 40.89
Shipping Weight (kg) 30.75
Cooling Method Fan
UPS Housing Material Polycarbonate
Primary UPS Height (mm) 361
Primary UPS Width (mm) 234
Primary UPS Depth (mm) 305
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode Efficiency Rating (100% Load) 94%
Audible Noise Audible Noise < 47dBA At Front Side 1 Meter
COMMUNICATIONS
Communications Interface USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network Management Cards SNMPWEBCARD; TLNETCARD;  WEBCARDLX 
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable 2 USB and 2 DB9 cables included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time 2-4 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 151
High Voltage Transfer to Battery Power (Setpoint) 282
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Hot swappable batteries
CERTIFICATIONS
UPS Certifications CE
UPS Certification Details CE 62040
WARRANTY
Product Warranty Period (International) 2-year limited warranty

Pickup is available at our Baghdad Branch.

Location: Baghdad-62st-near Saj Alreef

Call/Whatsapp: 07834927717

Order is usually ready within 24 hours.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

More from All Products
HP Ink 123
10,500 IQD
HP 652 Black/Tri-color Original Ink Cartridge
20,000 IQD
HP 953 Original Ink Cartidge
from 33,000 IQD
HP Ink 72
125,000 IQD
HP 711 80-ml DesignJet Ink Cartridge
51,000 IQD
HP Toner 415A
from 120,000 IQD
Recently viewed