Nominal Voltage Number of cell Design Life Nominal Capacity 77℉(25℃) Internal Resistance Self-Discharge Operating Temperature Range Max. Discharge Current 77℉(25℃) Short Circuit Current Charge Methods: Constant Voltage Charge 77℉(25℃) 12V 6 10 years 5 hour rate (11.3A, 10.5V) 56.5Ah 1 hour rate (44.2A, 9.6V) 44.2Ah Fully Charged battery 77 (25℃) mOhms 3% of capacity declined per month at 20℃(average) Discharge -20~60℃ Charge -10~60℃ Storage -20~60℃ 650A(5s) 1700A Cycle use Maximum charging current 19.5A Temperature compensation -30mV/℃ Standby use Temperature compensation -20mV/℃ 10 hour rate (6.5A, 10.8V) 65.0Ah ≤6.8 2.40-2.45VPC 2.20-2.30VPC
Nominal Voltage Number of cell Design Life Nominal Capacity 77℉(25℃) Internal Resistance Self-Discharge Operating Temperature Range Max. Discharge Current 77℉(25℃) Short Circuit Current Charge Methods: Constant Voltage Charge 77℉(25℃) 12V 6 5 years 20 hour rate (1.20A, 10.5V) 24Ah 10 hour rate (2.37A, 10.5V) 23.7Ah 5 hour rate (4.10A, 10.5V) 20.5Ah 1 hour rate (16.0A, 9.6V) 16.0Ah Fully Charged battery 77 (25℃) mOhms 3% of capacity declined per month at 20℃(average) Discharge -20~60℃ Charge -10~60℃ Storage -20~60℃ 300A(5s) 1200A Cycle use 2.40-2.45VPC Maximum charging current 9.6A Temperature compensation -30mV/℃ Standby use 2.23-2.30VPC Temperature compensation -20mV/℃
utput power capacity
1.6kWatts / 2.0kVA
Output Connections
(4) IEC 320 C13 (Battery Backup)
(4) IEC 60320 C13 (Battery Backup)
Nominal Output Voltage
230V
Nominal Input Voltage
230V
Input Connections
IEC 60320 C14
Cord Length
1.5meters
APC Easy UPS On-Line SRV 2000VA 230V
High quality, Double-conversion On-line UPS designed for essential power protection needs even in the most unstable power conditions.
Automatic internal bypass
Pure static bypass switch without bridging contactor securing a fast and reliable transfer to and from bypass, rated for 125% nominal load.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Intelligent Card Slot
Customize UPS capabilities with management card
Output power capacity
410 Watts / 750VA
Output Connections
(4) IEC 60320 C13 (Battery Backup)
Nominal Output Voltage
230V
Nominal Input Voltage
230V
Input Connections
IEC 60320 C14
Cord Length
1.2meters
APC Back-UPS 750VA, 230V, AVR, IEC Sockets
Battery Backup & Surge Protector for Electronics and Computers
Includes: User manual
Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
PowerChute Personal Edition OS Compatibility
This software supports numerous operating systems and processors. For further information, please bra href="https://www.apc.com/wp/?um=300"click here./a
Back-UPS Features & Benefits
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Manageability
LED status display
Quickly understand unit and power status with visual indicators.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Availability
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Protection
Battery and surge protected outlets
Back up and protect your hardware and data during power outages, surges and spikes .
Surge only outlets
Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
Marketing features
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Max. Capacity Used
100%
Output power capacity
900 Watts / 1.6kVA
Output Connections
(6) IEC 60320 C13 (Battery Backup)
Nominal Output Voltage
230V
Nominal Input Voltage
230V
Input Connections
IEC 60320 C14
Cord Length
1.2meters
APC Back-UPS 1600VA, 230V, AVR, IEC Sockets
Battery Backup & Surge Protector for Electronics and Computers
Includes: User manual
Automatic Voltage Regulation (AVR)
Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
PowerChute Personal Edition OS Compatibility
This software supports numerous operating systems and processors. For further information, please bra href="https://www.apc.com/wp/?um=300"click here./a
USB connection
Use your PC to access additional power protection and management features for your UPS via a USB Port.
cable length
1.22 m
colour
Black
depth
39 cm
height
19 cm
mounting preference
No preference
net weight
7.6 kg
mounting mode
Not rack-mountable
two post mountable
0
USB compatible
No
width
14 cm
Input
network frequency
50/60 Hz +/- 5 Hz auto-sensing
plug standard
IEC 60320 C14
input voltage limits
140...300 V
number of cables
1
input voltage
230 V
cos phi
0.54
Output
rated power in W
650 W
Maximum configurable power in W
650 W
output frequency
50/60 Hz +/- 1 Hz sync to mains
UPS type
Line interactive
Wave type
Stepped approximation to a sinewave
nb of power socket outlets
6 IEC 60320 C13
curve equation
Efficiency
curve fixed loss
0.0247
curve load maximum
100 %
curve load minimum
3 %
curve proportional loss
0
curve square loss
0.0026
curve X-axis maximum