Zeus Zeus 1000VA Online UPS
The Zeus 1000VA Online UPS is your best bet for reliable, secure power protection. With its large 1000VA capacity and advanced online topology, you can expect a high degree of protection when using a variety of sensitive electronics. Designed for business-critical applications, this UPS offers superior power conditioning, long-term backup, and constant regulation for superior protection. 1 Year Warranty
240,000 IQD 215,000 IQD
APC APC Easy UPS SMV 3000VA, Universal Outlet, 230V SMV3000AI-MS - Black
Product Description • Best Value UPS with Battery Backup & Surge Protection for Electronics and Computers • Power Factor : More real output power with 0.7 Pf. • Pure Sinewave : A pure form of sinewave designed to emulate utility power, will support your device upon battery backup • Generator Compatible : Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. • Rugged Metal Construction : Easy UPS SMV is built with resilient sheet metal that rigidly holds and protects critical electrical components. • Automatic Voltage Regulation : Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment. • LCD Display : Intuitive interface provides detailed and accurate information at a glance. • Generous Number of Outlets : 6 battery backup and surge protected outlets are included across all SMV Easy UPS. • Battery Connector : A convenient way to disconnect the battery for transport. • Communication Ports : USB and serial ports for UPS management. • Safety Agency Approved : Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. What's in the box • 1 x APC Easy UPS SMV 3000VA, Universal Outlet, 230V SMV3000AI-MS - Black • 1 x Documentation CD • 1 x USB cable • 1 x User manual About Us SNS Network, a MSC Status Company was established in 1998, incorporated in 2000 and the head office is located in Ipoh, Perak. We have setup three offices strategically located at the Major cities of Malaysia; Perai (Penang), Ipoh (Perak), and Petaling Jaya (Selangor). SNS Network is also the first company to be awarded as Intel® Authorized Solution Provider (IASP) in Perak. Besides being awarded by Intel as Intel® Premier Provider beginning from 2000 until now, we are further recognized as Intel® Certified Solutions Consultant and Intel® Certified Integration Specialist. We are also being recognized by Microsoft® as Microsoft® Gold Certified Partner with qualified Microsoft® Certified System Engineer expertise. With more than 10 years of outstanding technical expertise and experience, SNS Network delivers proven, flexible solutions that can enable our clients to become more adaptable, responsive, and profitable. We assist our clients in maximizing their information resources and enhancing their competitive advantage. As a leading technology provider with inherent strengths in the provision of scalable ICT solutions, SNS Network is geared to harness its domain-driven and knowledge-based expertise for the myriad of industries that we serves. Today ever changing market and intense competition has forced organizations to adapt and response quickly. At SNS, we understand that no two companies or industries are alike. Our solutions are designed and tailored to suit the industry, organization’s size, and the ultimate objectives.
955,000 IQD
APC APC Easy UPS SMV 1500VA, Universal Outlet, 230V
Output power capacity 700Watts / 1.0kVA Max Configurable Power (Watts) 700Watts / 1.0kVA Nominal Output Voltage 230V Output Frequency (not synced) 50/60 Hz +/-1 Hz Load Crest Factor 3 : 1 Topology Line Interactive Waveform type Sine wave Transfer Time 2ms typical Input Nominal Input Voltage 230V Input frequency 45 - 65 Hz (auto sensing) Input Connections IEC-320 C14 Input voltage range for main operations 160 - 295V Number of Power Cords 1 Other Input Voltages 220, 240 Batteries & Runtime Battery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof Typical recharge time 4hour(s) Expected Battery Life (years) 3 - 5 Battery Volt-Amp-Hour Capacity 150 Runtime View Runtime Graph View Runtime Chart Efficiency View Efficiency Graph Communications & Management Interface Port(s) USB Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm Physical Maximum Height 220MM, 22.0CM Maximum Width 160MM, 16.0CM Maximum Depth 410MM, 41.0CM Net Weight 13.6KG Shipping weight 16.6KG Shipping Height 339MM, 33.9CM Shipping Width 272MM, 27.2CM Shipping Depth 508MM, 50.8CM Environmental Operating Temperature 0 - 40 °C Operating Relative Humidity 0 - 90 % Operating Elevation 0-999.9meters Storage Temperature -10 - 40 °C Storage Relative Humidity 0 - 95 % Storage Elevation 0-3000meters Audible noise at 1 meter from surface of unit 45.0dBA Conformance Approvals CE Standard warranty 2 years repair or replace
545,000 IQD
Apc APC Smart-UPS 1500VA, Rack Mount, LCD 230V with SmartConnect Port
Main Input Voltage 120 V Other Input Voltage 110 V125 V Main Output Voltage 120 V Other Output Voltage 110 V125 V Rated power in W 900 W Rated power in VA 1440 VA Product or component type Uninterruptible power supply (UPS) Input Connection Type NEMA 5-15P output connection type 6 NEMA 5-15R Number of rack unit 2U Cable length 2.44 m Number of cables 1 Battery type Lead-acid battery Provided equipment Documentation CDInstallation guideRack mounting bracketsUSB cable Complementary Software package SmartConnect software for remote power monitoring feature availability varies by terms of use Batteries & Runtime Run Time View Runtime Graph action_new_window Efficiency View Efficiency Graph action_new_window Extended runtime 0 Number of battery filled slots 0 Number of battery free slots 0 Battery recharge time 3 h Number of battery replacement quantity 1 Battery life 4…6 year(s) Replacement battery APCRBC157 action_new_window Battery power in VAH 260 VAh runtime Battery charger power 86 W rated General Number of power module filled slots 0 Number of power module free slots 0 product web sub-family Cloud-enabled monitoring Redundant No Physical Colour Black Height 8.6 cm Width 43.2 cm Depth 47.7 cm Net weight 25.3 kg Mounting location Front Mounting preference Lower Mounting mode Rack-mounted Two post mountable 0 USB compatible Yes Input Input voltage limits 85...136 V adjustable93...130 V Network frequency 50/60 Hz +/- 3 Hz auto-sensing Output Harmonic distortion Less than 5 % Maximum configurable power in VA 1440 VA Maximum configurable power in W 900 W Transfer time 6 ms typical : 10 ms maximum UPS type Line interactive Wave type Sine wave Output frequency 50/60 Hz +/- 3 Hz sync to mains Conformance Product certifications cULusENERGY STAR V2.0 (USA) Equipment protection policy Lifetime : $150000 Environmental Acoustic level 45 dBA Heat dissipation 225 Btu/h Operating altitude 0...10000 ft Ambient air temperature for operation 0…40 °C Ambient air temperature for storage -15…45 °C Storage altitude 0.00…15240.00 m Relative humidity 0…95 % Storage Relative Humidity 0…95 % Communications & Management control panel Multifunction LCD status and control console Free slots 0 Communication port support SmartConnect Ethernet port: for cloud monitoring feature availability varies by terms of use Alarm Alarm when on battery : distinctive low battery alarm : configurable delays Surge Protection and Filtering Surge energy rate 680 J Noise suppression Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 23.5 cm Package 1 Width 61 cm Package 1 Length 59 cm Package 1 Weight 29.01 kg
920,000 IQD
Tripp-Lite TRIPP LITE SmartPro 230V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Network Card Options, USB, DB9 Serial
UPC Code 037332119780 UPS Type Line-Interactive OUTPUT Output Volt Amp Capacity (VA) 1500 Output kVA Capacity (kVA) 1.5 Output Watt Capacity (Watts) 940 Nominal Voltage Details 230V nominal output in battery mode Frequency Compatibility 50 / 60 Hz Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Line Mode) -18%, +8% Output Voltage Regulation (Battery Mode) +/- 5% Included Output Power Cables Includes 2 C13 to C14 output power cables Hot-Swap PDU options PDUBHV10 (2U / 8 C13 outlets) Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave Nominal Output Voltage(s) Supported 220V; 230V; 240V Output Receptacles (8) C13 Individually Controllable Load Banks No INPUT Rated input current (Maximum Load) 5A Nominal Input Voltage(s) Supported 230V AC UPS Input Connection Type C14 inlet UPS Input Connection Description Attached 15cm line cord with C14 inlet. The C14 inlet accepts user-supplied AC power cord with country-specific plug. UPS Input Cord Length (ft.) 0.5 UPS Input Cord Length (m) 0.2 Input Phase Single-Phase BATTERY Full Load Runtime (min.) 4.5 min. (940w) Half Load Runtime (min.) 13 min. (470w) Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible) DC System Voltage (VDC) 24 Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90% Internal UPS Replacement Battery Cartridge RBC51 (quantity 2) Battery Access Battery access door Battery Replacement Description Hot-swappable, user replaceable batteries Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151 to 282 Overvoltage Correction Input voltages between 245 and 282 are reduced by 12% Undervoltage Correction Input voltages between 177 and 199 are boosted by 14% Severe Undervoltage Correction Input voltages between 151 and 176 are boosted by 30% USER INTERFACE, ALERTS & CONTROLS Switches 2 Switches control off/on power status and alarm-cancel/self-test operation Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status Audible Alarm Audible alarm indicates power-failure and low-battery conditions LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 340 UPS AC Suppression Response Time Instantaneous UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet EMI / RFI AC Noise Suppression Yes PHYSICAL Installation Form Factors Supported with Included Accessories Tower Installation Form Factors Supported with Optional Accessories Wallmount (UPSWM - tower mounting kit) Primary Form Factor Tower Primary UPS Depth (mm) 191 Primary UPS Height (mm) 300 Primary UPS Width (mm) 183 Shipping Dimensions (hwd / cm) 39.62 x 26.42 x 27.43 Shipping Weight (kg) 14.74 UPS Housing Material Polycarbonate UPS Power Module Dimensions (hwd, cm) 29.97 x 18.29 x 19.05 UPS Power Module Weight (kg) 14.51 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 99 Battery Mode BTU / Hr. (Full Load) 657 AC Mode Efficiency Rating (100% Load) 97% COMMUNICATIONS Communications Interface USB PowerAlert Software For local monitoring via the UPS’s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable USB interface cable included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time 2-4 milliseconds Low Voltage Transfer to Battery Power (Setpoint) 151 High Voltage Transfer to Battery Power (Setpoint) 282 SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Hot swappable batteries Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS CERTIFICATIONS UPS Certifications Tested to UL1778 (USA); CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina) UPS Certification Details CE 62040 WARRANTY Product Warranty Period (International) 2-year limited warranty
480,000 IQD
Tripp-Lite Tripp-Lite SmartOnline 200-240V 10kVA 9kW Double-Conversion UPS, 6U
UTPUT Output Volt Amp Capacity (VA) 10000 Output kVA Capacity (kVA) 10 Output Watt Capacity (Watts) 9000 Output kW Capacity (kW) 9 Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less Power Factor 0,9 Crest Factor 3:1 Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V Nominal Voltage Details Voltage selection via front panel LCD interface Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating); Output frequency regulation +/- 0.05Hz (free running) Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 2% Output Receptacles Hardwire Output Receptacle Details Supports North American 208/240V* output (L1,L2,G) and International 230/220/240V (L,N,PE) hardwire output; *For 120V output with 208/240V (L1,L2,G) input wiring, use optional SU6000XFMR2U transformer Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave INPUT Rated input current (Maximum Load) 56.1A (200V), 54A (208V), 51A (220V), 48.8A (230V), 46.8A (240V) Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC UPS Input Connection Type Hardwire UPS Input Connection Description Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring Recommended Electrical Service 60A Input Phase Single-Phase BATTERY Full Load Runtime (min.) 4.3 min. (9000w) Half Load Runtime (min.) 12.5 min. (4500w) Expandable Battery Runtime Supports extended runtime with optional external battery packs External Battery Pack Compatibility BP240V10RT3U; BP240V787C-1PH DC System Voltage (VDC) 240 Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge) Battery Replacement Description Hot-swappable, user replaceable external battery packs Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description 2% output voltage regulation in standard online, double-conversion mode Overvoltage Correction Corrects overvoltages up to 300V Undervoltage Correction Corrects undervoltages as low as 100V USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual) Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement Alarm Cancel Operation Alarm cancel switch Audible Alarm Unique audible alarms for all major UPS, environmental and power conditions (see manual) LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options SURGE / NOISE SUPPRESSION UPS AC Suppression Response Time Instantaneous EMI / RFI AC Noise Suppression Yes PHYSICAL Included Mounting Accessory Description 2 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included Installation Form Factors Supported with Optional Accessories 2 post rackmount (2POSTRMKITHD) Optional Mounting Accessory Notes 2 sets of 2POSTRMKITHD required for 2 post rackmount installation of all included components Primary Form Factor Rackmount UPS Power Module Dimensions (hwd, cm) 13.06 x 44.45 x 65.58 Rack Height (U Spaces) 6 Maximum Device Depth (cm) 82.55 Minimum Required Rack Depth (cm) 95.25 UPS Power Module Weight (kg) 19.50 UPS Dimensions Details Includes 3U UPS/power module, 3U external battery pack plus SUPDMB710HW PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed Included Battery Pack Weight (kg) 71.99 Shipping Dimensions (hwd / cm) 78.74 x 66.04 x 104.14 Shipping Weight (kg) 148.58 Cooling Method Fan UPS Housing Material Steel Maximum Device Depth (mm) 826 Primary UPS Height (mm) 131 Primary UPS Width (mm) 445 Primary UPS Depth (mm) 656 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 3415 AC Economy Mode BTU / Hr. (Full Load) 1280 Battery Mode BTU / Hr. (Full Load) 4593 AC Mode Efficiency Rating (100% Load) 91% AC Economy Mode Efficiency Rating (100% Load) 96% Operating Elevation (ft.) 0-3000m (0 to 10,000 ft.) Audible Noise 60 dBA at front side 1 meter Operating Elevation (m) 0-3000 m COMMUNICATIONS Communications Interface USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface Network Management Cards SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD Network Monitoring Port Description Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable USB, DB9 serial and EPO cables included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time No transfer time (0 ms.) in online, double-conversion mode Transfer Time (Economy Mode) 8 ms. typical power failure response in optional economy mode Low Voltage Transfer to Battery Power (Setpoint) 100V High Voltage Transfer to Battery Power (Setpoint) 300V SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported Economy Mode Operation Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes. High Availability UPS Features Automatic inverter bypass; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch Green Energy-Saving Features High efficiency economy mode operation; Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); CE; Meets FCC Part 15 Category A (EMI) UPS Certification Details IEC 61000-4-5 1995 B Surge Immunity WARRANTY Product Warranty Period (Worldwide) 2-year limited warranty Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance
4,000,000 IQD
Tripp-Lite Tripp-Lite SmartOnline 208/230V 3kVA 2.7kW Double-Conversion UPS, 2U Rack/Tower SUINT3000LCD2U
OUTPUT Output Volt Amp Capacity (VA) 3000 Output kVA Capacity (kVA) 3 Output Watt Capacity (Watts) 2700 Output kW Capacity (kW) 2.7 Output Capacity Details DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1890 watts for 208/220/230/240V output voltages; Max output is reduced to 2160W at 200V output voltage in all operating modes OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits). Power Factor 0.9 Crest Factor 3:1 Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V Nominal Voltage Details Nominal output voltage is user configured on first power-on Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 2% Output Receptacles (8) C13; (2) C19 Included Output Power Cables Includes 2 C13 to C14 and 1 C19 to C20 power cables Load Management Receptacles Two switchable 4 outlet load banks (3 C13 and 1 C19 per bank) Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave INPUT Rated input current (Maximum Load) 14.97A Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC UPS Input Connection Type C20 inlet Input Phase Single-Phase BATTERY Full Load Runtime (min.) 5 min. (2700w) Half Load Runtime (min.) 13.5 min. (1350w) Expandable Battery Runtime Supports extended runtime with optional external battery packs External Battery Pack Compatibility BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) DC System Voltage (VDC) 72 Battery Recharge Rate (Included Batteries) 3.0 hours from 10% to 90% (typical, full load discharge) Internal UPS Replacement Battery Cartridge RBC72S Battery Access Front panel battery access door Battery Replacement Description Hot-swappable, replaceable batteries Expandable Runtime Yes
1,875,000 IQD
Tripp-Lite Tripp-Lite SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, SMX3000XLRT2UA
3kVA / 3000VA / 2700W line interactive 2U rack/tower UPS, Sine Wave Extended runtime options up to 2700W, 0.9 Power Factor, Interactive LCD interface 98% line-mode efficiency, 2 switched load banks, 4 post mounting kit USB, RS232, EPO and slot for network management card options230V C20 inlet, 8 C13 & 1 C19 outlets Add optional WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature 2-year limited warranty
1,000,000 IQD
Tripp-Lite Tripp-Lite SmartOnline 230V 3kVA 2700W On-Line Double-Conversion UPS, Tower, SUINT3000XLCD
OUTPUT Output Volt Amp Capacity (VA) 3000 Output kVA Capacity (kVA) 3 Output Watt Capacity (Watts) 2700 Output kW Capacity (kW) 2.7 Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits) Power Factor 0.9 Crest Factor 3:1 Nominal Output Voltage(s) Supported 220V; 230V; 240V Nominal Voltage Details 230V default Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. FREQUENCY CONVERSION MODE: Output is regulated to +/-0.05Hz of selected output frequency when input is 40 to 70Hz; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz. BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal. Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 3% Output Receptacles (6) C13; (1) C19 Included Output Power Cables Includes three C13 to C14 power cables Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave INPUT Rated input current (Maximum Load) 14.6A 220V; 14.0A 230V; 13.4A 240V Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC Nominal Input Voltage Description 230V factory default UPS Input Connection Type C20 inlet Input Circuit Breakers 20A UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3.1 Recommended Electrical Service 230V Input Phase Single-Phase BATTERY Full Load Runtime (min.) 4.4 min. (2700w) Half Load Runtime (min.) 11.2 min. (1350w) Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP72V15-2U (limit 1); BP72V18-2US (multi-pack compatible); BP72V28RT-3U (multi-pack compatible) Expandable Runtime Description External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details DC System Voltage (VDC) 72 Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge) Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description Online, double-conversion power conditioning Overvoltage Correction 2% output voltage regulation during overvoltages to 280 Undervoltage Correction 2% output voltage regulation during undervoltages to 80V (50% load), 175V (100% load)
1,310,000 IQD
Tripp-Lite Tripp-Lite SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower SMARTINT3000VS
OUTPUT Output Volt Amp Capacity (VA) 3000 Output kVA Capacity (kVA) 3 Output Watt Capacity (Watts) 2250 Output kW Capacity (kW) 2.25 Output Capacity Details 2250W maximum with up to 1 external battery pack; 1500W maximum with 2 or more external battery packs Power Factor 0.75 Nominal Output Voltage(s) Supported 220V; 230V; 240V Nominal Voltage Details 230v nominal inverter output voltage Frequency Compatibility 50 / 60 Hz Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Line Mode) -19% +8% Output Voltage Regulation (Battery Mode) +/- 5% Output Receptacles (8) C13; (1) C19 Included Output Power Cables Includes 3 C13 to C14 output power cables Load Management Receptacles Three switchable two-outlet C13 load banks Output Circuit Breakers 10A (x2) - each breaker protects 4 C13 outlets each, C19 is unbreakered Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave INPUT Rated input current (Maximum Load) 15.4A Nominal Input Voltage(s) Supported 230V AC UPS Input Connection Type C20 inlet UPS Input Connection Description User supplies input cabling with C19 output connection Input Phase Single-Phase BATTERY Full Load Runtime (min.) 4 min. (2250w) Half Load Runtime (min.) 14 min. (1125w) Expandable Battery Runtime Extended runtime supported via optional external battery packs External Battery Pack Compatibility BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible) DC System Voltage (VDC) 48 Battery Recharge Rate (Included Batteries) Less than 4 hours from 10% to 90% (typical, full load discharge) Internal UPS Replacement Battery Cartridge RBC54 Battery Access Battery access door Battery Replacement Description Hot-swappable, user replaceable batteries Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151V to 282V Overvoltage Correction Input voltages between 245 and 282 are reduced by 12% Undervoltage Correction Input voltages between 177 and 199 are boosted by 14% Severe Undervoltage Correction Input voltages between 151 and 176 are boosted by 30% USER INTERFACE, ALERTS & CONTROLS Switches 2 Switches control off/on power status and alarm-cancel/self-test operation Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 480 UPS AC Suppression Response Time Instantaneous EMI / RFI AC Noise Suppression Yes PHYSICAL Primary Form Factor Tower UPS Power Module Dimensions (hwd, cm) 36.07 x 23.37 x 30.48 UPS Power Module Weight (kg) 27.67 Shipping Dimensions (hwd / cm) 50.55 x 38.35 x 40.89 Shipping Weight (kg) 30.75 Cooling Method Fan UPS Housing Material Polycarbonate Primary UPS Height (mm) 361 Primary UPS Width (mm) 234 Primary UPS Depth (mm) 305 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC Mode Efficiency Rating (100% Load) 94% Audible Noise Audible Noise < 47dBA At Front Side 1 Meter COMMUNICATIONS Communications Interface USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface Network Management Cards SNMPWEBCARD; TLNETCARD; WEBCARDLX Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable 2 USB and 2 DB9 cables included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time 2-4 milliseconds Low Voltage Transfer to Battery Power (Setpoint) 151 High Voltage Transfer to Battery Power (Setpoint) 282 SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Hot swappable batteries CERTIFICATIONS UPS Certifications CE UPS Certification Details CE 62040 WARRANTY Product Warranty Period (International) 2-year limited warranty
950,000 IQD
Tripp-Lite Tripp-Lite SmartOnline 230V 2kVA 1800W On-Line UPS, Tower, Network Card Options, LCD,SUINT2000XLCD
OVERVIEW UPC Code 037332177445 UPS Type Line-Interactive OUTPUT Output Volt Amp Capacity (VA) 1500 Output kVA Capacity (kVA) 1.5 Output Watt Capacity (Watts) 900 Nominal Voltage Details 230V nominal output in battery mode Frequency Compatibility 50 / 60 Hz Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Battery Mode) +/- 5% UPS Output Receptacles (Surge Suppression Only) 6 UPS outlets, 2 surge-only outlets Hot-Swap PDU options PDUBHV10 (2U / 8 C13 outlets) Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave Nominal Output Voltage(s) Supported 220V; 230V; 240V Output Receptacles (8) C13 Individually Controllable Load Banks No INPUT Rated input current (Maximum Load) 9A Nominal Input Voltage(s) Supported 230V AC UPS Input Connection Type C14 inlet Input Circuit Breakers 10A fuse UPS Input Cord Length (ft.) 6 UPS Input Cord Length (m) 1.8 Input Phase Single-Phase BATTERY Half Load Runtime (min.) 10 minutes (450 watts) DC System Voltage (VDC) 24 Battery Recharge Rate (Included Batteries) Less than 8 hours from 10% to 90% Internal UPS Replacement Battery Cartridge RBC51 (requires 2) Expandable Runtime No VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with a correction range from 170V to 280V Overvoltage Correction Input voltages between 247 and 280 are reduced by 15% Undervoltage Correction Input voltages between 170 and 207 are boosted by 18% USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Output load in watts, Battery voltage and Estimated runtime in minutes Switches Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch Audible Alarm Audible alarm indicates power-failure and low-battery conditions SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 455 UPS AC Suppression Response Time Instantaneous UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet EMI / RFI AC Noise Suppression Yes PHYSICAL Cooling Method Fan Installation Form Factors Supported with Included Accessories Tower Primary Form Factor Tower Primary UPS Depth (mm) 394 Primary UPS Height (mm) 203 Primary UPS Width (mm) 146 Shipping Dimensions (hwd / cm) 28.70 x 23.11 x 49.02 Shipping Weight (kg) 12.34 UPS Power Module Dimensions (hwd, cm) 20.32 x 14.60 x 39.37 UPS Power Module Weight (kg) 11.20 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 79 Battery Mode BTU / Hr. (Full Load) 918 AC Mode Efficiency Rating (100% Load) 95% COMMUNICATIONS Communications Interface USB (HID enabled) Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert Communications Cable USB cabling included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time 6 milliseconds Low Voltage Transfer to Battery Power (Setpoint) 170V (factory setting), 175V (medium setting), 180V (narrow setting) High Voltage Transfer to Battery Power (Setpoint) 280V (factory setting), 275V (medium setting), 270V (narrow setting) SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Hot swappable batteries Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS CERTIFICATIONS UPS Certifications CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia) UPS Certification Details EN62040-1, EN62040-2 Class A WARRANTY Product Warranty Period (International) 2-year limited warranty
915,000 IQD
Tripp-Lite Tripp-lite SmartOnline 230V 1kVA 900W On-Line UPS, Tower, Network SUINT1000XLCD
\ Specifications OVERVIEW UPC Code 037332190659 UPS Type On-Line INPUT Rated input current (Maximum Load) 4.9A 220V; 4.7A 230V; 4.5A 240V Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC Nominal Input Voltage Description 230V factory default UPS Input Connection Type C14 inlet Input Circuit Breakers 10A UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3.1 Recommended Electrical Service 230V Input Phase Single-Phase OUTPUT Output Volt Amp Capacity (VA) 1000 Output Capacity (kVA) 1 Output Watt Capacity (Watts) 900 Output kW Capacity (kW) 0.9 Output Capacity Details OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 1 minute; 150% load for 30 seconds; Loads greater than 150% trigger immediate switchover to BYPASS (when input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when input voltage and frequency are OUTSIDE bypass limits) Power Factor 0.9 Crest Factor 3:1 Nominal Voltage Details 230V default Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details ON LINE MODE: Output frequency is automatically configured to match nominal input frequency on startup; Output matches input frequency when +/-5Hz of nominal; Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal; UPS switches to battery mode when input frequency is below 40Hz or above 70Hz; BATTERY MODE: Output is regulated to +/-0.05Hz of selected nominal Output Voltage Regulation (Line Mode) +/- 2% Output Voltage Regulation (Economy Line Mode) +/- 10% Output Voltage Regulation (Battery Mode) +/- 3% Included Output Power Cables Includes two C13 to C14 power cables Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave Nominal Output Voltage(s) Supported 220V; 230V; 240V Output Receptacles (4) C13 Individually Controllable Load Banks No BATTERY Battery Type Valve Regulated Lead Acid (VRLA) Full Load Runtime (min.) 4.8 min. (900w) Half Load Runtime (min.) 12.8 min. (450w) Expandable Battery Runtime Extended runtime supported via optional external battery packs Expandable Runtime Yes Expandable Runtime Description External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details External Battery Pack Compatibility BP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible) DC System Voltage (VDC) 24 Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge) VOLTAGE REGULATION Voltage Regulation Description Online, double-conversion power conditioning Overvoltage Correction 2% output voltage regulation during overvoltages to 280 Undervoltage Correction 2% output voltage regulation during undervoltages to 80V (50% load), 175V (100% load)